Installation instructions, only for experts

4. Installation and connection

Take the following points into account when positioning and connecting the
sauna heater:
WARNING!
Danger of electric shock
● The sauna heater may only be installed and connected when the
power supply is disconnected.
● The electrical connection may only be performed by a qualified electrician or
similarly qualified person.
● An all-pole disconnecting device with full cut-off must be fitted on-site in ac-
cordance with overvoltage category III.
● The Concept R mini sauna heater is a wall-mounted heater. Before starting
the heater, check that the heater has been firmly installed on the mounting rail.

4.1. Installation location and sensor position

Position the heater centrally in front of the air intake opening on the cabin wall.
Comply with the safety intervals to the cabin wall specified in Fig. 1.
Install the temperature sensor with excessive temperature controller to the cabin
wall above the centre of the sauna heater. Maintain a distance of 15 cm to the
sauna cabin roof.