Software Parameters

Parameter
0
Selecting this item exits to Running Mode
Read-Only Parameters
1
Model Number
2
Software Build
3
Hardware Version
4
Serial Number – Major (reserved)
5
Serial Number – Minor (reserved)
General Setup
10
Operating Mode
11
Display Intensity
13
Decimal Point Position
14
Keypad Mode
15
Keypad Scroll Delay
16
S1 / S2 Input Edge & Prescaler Configuration
18
Power-up Mode
19
Power-up Value
Display & Control Loop Setup
20
Display Minimum
21
Display Maximum
23
Accel Setting
24
Decel Setting
26
Proportional Gain
27
Integral Gain
29
Pulse Accumulation Limit
Signal Input #1 (S1) Setup
30
S1 Display Reference
31
S1 Reference RPM
32
S1 Pulses per Revolution
33
S1 Deadband (Follower Mode Only)
Description
14
Value Range
(units)
n/a
10 – MD10P Unit
11 – MD3P Unit
13 – MD3E Unit
1 – 9999
1 – 9999
n/a
n/a
1 – Rate Mode
2 – Time Mode
3 – Follower Mode
0 – 31 (Dim – Bright)
0 – DP Disabled (XXXX)
1 – X.XXX
2 – XX.XX
3 – XXX.X
4 – XXXX.
1 – Linear, Constant Rate
2 – Non-linear, Accelerating Rate
0 – 30 (Fast – Slow)
0 – S1 is Rising/1
S2 is Rising/1
1 – S1 is Falling/1
S2 is Rising/1
2 – S1 is Falling/4
S2 is Rising/1
3 – S1 is Falling/16 S2 is Rising/1
4 – S1 is Rising/1
S2 is Falling/1
5 – S1 is Falling/1
S2 is Falling/1
6 – S1 is Falling/4
S2 is Falling/1
7 – S1 is Falling/16 S2 is Falling/1
8 – S1 is Rising/1
S2 is Falling/4
9 – S1 is Falling/1
S2 is Falling/4
10 – S1 is Falling/4 S2 is Falling/4
11 – S1 is Falling/16 S2 is Falling/4
12 – S1 is Rising/1
S2 is Falling/16
13 – S1 is Falling/1 S2 is Falling/16
14 – S1 is Falling/4 S2 is Falling/16
15 – S1 is Falling/16 S2 is Falling/16
1 – Default to Zero Display
2 – Default to Power-up Value
3 – Default to Previous Running Val.
0 – 9999 (Display Units)
0 – 9998 (Display Units)
1 – 9999 (Display Units)
1 – 9999 (Display Units)
1 – 9999 (Display Units)
0 – 9999 (Not Unit-specific)
1 – 9999 (Not Unit-specific)
2 – 5000 (Not Unit-specific)
0 – 9999 (Display Units)
0 – 9999 (RPM)
1 – 2048 (PPR)
0 – 1000 (Seconds)
Factory
User
Default
Settings
n/a
10, 11, or
13
n/a
n/a
n/a
n/a
1
20
0
2
10
0
3
0
0
2400
2500
2500
0
5000
15
2400
2400
1
0

Publicité