Caution: The PU-E cord should not be grouped with other wires or cords. For applications with PU-E
wire over 6 feet long, or noisy environments, a shielded cable is recommended. Connect the shield to
the common terminal on the MDP, leaving the shield on the PU-E end fl oating.
Electrical Installation & Diagrams
P1 Terminal Block Hook-Up Diagrams
MDP
MASTER
MDP
FOLLOWER
FUSE
N
MD10P = 7.5 Amp*
P1-1
MD3P = 15 Amp*
L
P1-2
-A
-ARM
P1-3
+A
+ARM
P1-4
COM
P1-5
COMMON
black
+5V
P1-6
red
+5VDC
S1
P1-7
SIGNAL
white
S2
P1-8
**Jog Input
NO
Alarm Output - Normally Open
P1-9
Alarm Output - Common
C
P1-10
NC
Alarm Output - Normally Closed
P1-11
User Input 1
IN1
P1-12
**INHIBIT
COM (P1-5)
* For AC inputs utilizing two hot lines, both inputs should be
protected with appropriately sized fuses or circuit breakers.
** P1-8 & P1-12 user input may be programmed
for a number of functions. Including (jog, inhibit, etc.)
FUSE
N
MD10P = 7.5 Amp*
P1-1
MD3P = 15 Amp*
L
P1-2
-A
-ARM
P1-3
+A
+ARM
P1-4
COM
P1-5
COMMON
+5V
P1-6
+5VDC
S1
P1-7
SIGNAL 1
S2
P1-8
SIGNAL 2
NO
Alarm Output - Normally Open
P1-9
C
Alarm Output - Common
P1-10
Alarm Output - Normally Closed
NC
P1-11
IN1
User Input 1
P1-12
**
INHIBIT
COM (P1-5)
* For AC inputs utilizing two hot lines, both inputs should be
protected with appropriately sized fuses or circuit breakers.
** P1-8 & P1-12 user input may be programmed
for a number of functions. Including (jog, inhibit, etc.)
8
AC INPUT
}
85-265VAC
AC INPUT
MOTOR
}
Form C
Relay Output
(Programmable)
black
white
}
AC INPUT
85-265VAC
AC INPUT
MOTOR
black
red
white
}
Form C
Relay Output
(Programmable)
PICK-UP MOUNTED
TO MOTOR SHAFT
(Mounts on rotating
end shaft with 10-32
tapped hole, 1/2" deep)
FOLLOWER PICK-UP
MOUNTED TO
MOTOR SHAFT
(Mounts on rotating
end shaft with 10-32
tapped hole, 1/2" deep)