P1 Terminal Block Descriptions
P1-1 (AC / N) – For single phase AC lines connect the Neutral side of your AC line to this terminal.
For systems with two hot AC lines, connect either of the Hot AC lines to this terminal.
P1-2 (AC / L) – For single phase AC lines connect the Hot side of your AC line to this terminal. For
systems with two hot AC lines, connect either of the Hot AC lines to this terminal.
P1-3 (-A) - This is the -Armature terminal. For normal rotation of your motor you should connect
the -Armature lead of your motor to this terminal. The +Armature lead of your motor will be
connected here when a reverse directional rotation of the armature is desired.
P1-4 (+A) - This is the +Armature terminal. For normal rotation of your motor you should connect
the +Armature lead of your motor to this terminal. The -Armature lead of your motor will be
connected here when a reverse directional rotation of the armature is desired.
P1-5 (COM) – This is the common point for the control logic. The speed sensor common lead as
well as any other source needing to reference the control common will be connected to this
terminal.
P1-6 (+5V) – This is a self-contained +5VDC power supply capable of up to 50mA. The speed sensor
supply lead can be connected to this terminal for its power source.
P1-7 (S1) – This is the signal input terminal for the motor's digital pickup or encoder.
P1-8 (S2) – This input can be programmed to perform a number of advanced functions. In Follower
Mode, this input is the signal input terminal for the master's digital pickup or encoder. In Master
modes (Rate and Time), this input can be confi gured to function as an emergency stop, inhibit,
or jog command.
P1-9 (NO) – This is the normally-open contact of the user assignable relay output.
P1-10 (C) – This is the common contact of the user assignable relay.
P1-11 (NC) – This is the normally-closed contact of the user assignable relay output.
P1-12 (IN1) – This input can be programmed to perform a number of advanced functions. It can be
confi gured to function as an emergency stop, inhibit, or jog command.
N
P1-1
L
P1-2
-A
-ARM
P1-3
+A
P1-4
+ARM
COM
P1-5
COMMON
+5V
P1-6
+5VDC
S1
P1-7
SIGNAL
S2
P1-8
*Jog Input
NO
P1-9
C
P1-10
NC
P1-11
IN1
P1-12
Ground Lug
MD3E
*
P1-8 & P1-12 user input may be programmed
for a number of functions. Including (jog, inhibit, etc.)
9
AC INPUT
}
85-265VAC
AC INPUT
MOTOR
PICK-UP MOUNTED
TO MOTOR SHAFT
black
red
white
Alarm Output - Normally Open
}
(Mounts on rotating
Form C
Alarm Output - Common
end shaft with 10-32
Relay Output
tapped hole, 1/2" deep)
Alarm Output - Normally Closed
(Programmable)
User Input 1
*INHIBIT
COM (P1-5)