ALARM MESSAGES
In the event the appliance presents operational problems, perform these simple checks to verify if repairs are required. If the
problem persists even after these verifications, contact a dealer in the area and then inform the Manufacturer about this anomaly,
using the form indicated in the last page of this manual.
The use of mobile phones, CB or working in presence of magnetic fields (high voltage electric pylon) can jeopardise the
operation of the monitor.
The user is warned by means of a message inside a generic window, having the required information
Press the function key
triggered simultaneously.
HIGH 1 -
Module Offline.
2
-
Module temperature.
3
-
Motor overload.
MEDIUM 1 -
Motor speed.
2
-
Shaft confirmation.
3
-
Encoder failure.
LOW 1 -
Low/High fan speed.
2
-
Cardan speed.
3
-
Hopper level.
NOTE: In the event several alarms are triggered simultaneously, they will be displayed according to their priority
ALARM
Code G19503490
USE AND MAINTENANCE
to deactivate the alarm displayed and reset the display to the previous state or pass to another alarm if
DESCRIPTION / CAUSE
NOT CONNECTED MCM MODULE ALARM
Indicates that the monitor does not detect the connection
with MCM module
MCM MODULE CRITICAL TEMPERATURE ALARM
Indicates that the management module of the motor is
close to the maximum temperature.
ATTENTION
ACTION
Verify the electrical connections inside
the main electric panel
Switch off the system and open the
main electric panel to make air circulate.
If the problem persists contact the
After-Sales Centre