Installation And Connection; Distances, Tolerances And Measuring Accuracy - Balluff IO-Link BML SL1-ALZ0-U1ZZ Serie Notice D'utilisation

Système de mesure de déplacement à codage magnétique absolu
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

BML SL1-ALZ0-U1ZZ-_ U1L-_ _
Absolute Magnetically Coded Position Measuring System
4

Installation and connection

4.1
Distances, tolerances and measuring
accuracy
The different mounting tolerances must be met depending
on the required measuring accuracy (see different working
ranges and maximum function range in Tab. 4-1).
During assembly, make sure that the sensor head is
correctly positioned over the magnetic tape. The distances
and tolerances must be complied with to ensure the
correct function and linearity class of the system specific to
the application.
Fig. 4-1:
Distances and tolerances with linear applications
Z
(gap between sensor/magnetic tape)
Z
(gap between sensor/magnetic tape
with cover strip)
Y (side offset)
Pitch
Yaw
Roll
Max. non-linearity
of entire system
(sensor head + magnetic tape)
Non-linearity of sensor head
Hysteresis
Repeat accuracy
Tab. 4-1:
Working ranges, angles, distances and tolerances and
measuring accuracy
8
english
27.3
Y
Z
Working range 1
≤ 0.4 mm
≤ 0.25 mm
±0.5 mm
±15 µm
±5 µm
≤ 1 µm
≤ 1 µm
–Roll
+Roll
5
5
+Yaw
–Yaw
–Pitch
Z
+Pitch
Working range 2
≤ 1.0 mm
≤ 0.85 mm
±1.0 mm
±0.5°
±0.2°
±0.5°
±40 µm
±30 µm
≤ 2 µm
≤ 2 µm
Active measuring surface
Free area of magnetizable
material
Direction of travel
Forwards, A (Sin) before B
(Cos).
Function range
≤ 1.3 mm
≤ 1.15 mm
±1.5 mm
±100 µm
±40 µm
≤ 2 µm
≤ 2 µm

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Io-link bml sl1-alz0-u1l serie

Table des Matières