Electrical Connection; Connector S284/Cable Connection Ka; Connector S4 - Balluff IO-Link BML SL1-ALZ0-U1ZZ Serie Notice D'utilisation

Système de mesure de déplacement à codage magnétique absolu
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

BML SL1-ALZ0-U1ZZ-_ U1L-_ _
Absolute Magnetically Coded Position Measuring System
4
Installation and connection (continued)
4.3

Electrical connection

Depending on the model, the electrical connection is made
using a cable or a connector.
The connection or pin assignments for the respective
version can be found in Tab. 4-3 and Tab. 4-4.
4.3.1

Connector S284/cable connection KA_ _

S284
Cable
Signal
-pin
color
IO-Link with 1Vpp
(BML SL1-ALZ0-
U1ZZ-AU1L
-S284/KA_ _)
1
WH
+B (+Cos)
2
BN
−B (−Cos)
3
GN
Not used
4
YE
Not used
5
GY
C/Q
6
PK
Not used
7
BU
L–
8
RD
L+
9
BK
−A (−Sin)
10
VT
+A (+Sin)
11
GY PK
Not used
12
RD BU
Not used
PH
Shield
Unassigned leads must not be connected.
1)
Tab. 4-3:
Pin assignment of connector S284/cable connection KA_ _
4.3.2

Connector S4

S4
Cable
Signal
-pin
color
IO-Link without
1Vpp
(BML SL1-ALZ0-
U1ZZ-ZU1L-S4)
1
BN
L+
2
WH
Not used
3
BU
L–
4
BL
C/Q
1)
Unassigned leads must not be connected.
Tab. 4-4:
Pin assignment of S4 connector
www.balluff.com
Description
Cosine-shaped voltage signal
Cosine-shaped voltage signal,
inverted
1)
1)
Communication line
1)
Sensor ground (0 V)
Supply voltage 18...30 V DC
Sine-shaped voltage signal
Sine-shaped voltage signal
1)
1)
Connector housing/shield
Description
Supply voltage 18...30 V DC
1)
Sensor ground (0 V)
Communication line
If the sensor is supplied with voltage that is
isolated from the processing electronics, the
GND for this voltage must be connected to the
GND of the processing electronics.
Note the information on shielding and cable
routing on page 12.
Fig. 4-6:
Pin assignment of M12 plug (view from
above on sensor head)
3
4
Fig. 4-7:
Pin assignment of S4 connector (view
from above on sensor head)
english
2
1
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Io-link bml sl1-alz0-u1l serie

Table des Matières