CAUTION:
• The appliance's efficiency can be reduced if the pre-filter is not cleaned regularly.
Never use a pre-filter that is still damp.
The pre-filter is the only filter which can be re-used and washed with water. The particle, NanoCaptur
and active carbon filters cannot be cleaned and re-used. Never wash with water.
To replace the filters, follow the instructions in the section « Disassembling/Reassembling filters ».
Your replacement filters are available under the following codes:
Filtre
Allergy+ filter
Active carbon filter
NanoCaptur+ filter
IMPORTANT: Resetting the filters
The reset light flashes when a filter needs to be replaced or cleaned (Prefilter). Once the filter has
been replaced, hold down the reset button for 3 seconds.
Forced reset:
If you have replaced a filter before its end of life, force the reset of the filter replacement cycle:
1. Hold the reset button for 3 seconds.
2. Press the reset button briefly to select the filter you have changed.
3. After selecting the filter to reset, hold the reset button for 3 seconds. The new filter life is then
reset.
4. If the reset filter button is not is activated for 10 seconds in forced reset mode, the reset mode
is canceled.
« TIPS FOR CHANGING FILTERS »
• Avoid handling used filters if you suffer from allergies or asthma.
• Wear gloves when changing the filters, or wash your hands well afterwards.
• Put used filters directly into a closed, air-tight bag before throwing them away to
avoid spreading pollutants.
POLLUTION SENSORS
The particles sensor and gas sensor (model PU608x only) need to be cleaned regularly (every 2
months) and appropriately.
Make sure you turn off and unplug the appliance before cleaning the pollution sensors and follow the
recommendations below:
1. Clean the air inlet and outlet using a soft brush or cloth.
2. Open the sensor cover located on the right-hand side of the appliance.
3. Lightly wet a cotton swab and remove any dust from the lens and the inlet/outlet. Wipe using
a dry cotton swab.
4. Clean the gas sensor using a soft brush or vacuum cleaner.
1
20
.
2
Code PU608x
XD6077
XD6062
XD6081
.
3
4