PRO-POINT 8866626 Consignes De Sécurité page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8866626
STORAGE
1.
Before storing the compressor for a prolonged period, use an air
blowgun to clean all dust and debris from the compressor.
2.
Disconnect the power cord and coil it up on the handle.
3.
Open the drain valve to release all pressure from the tanks. This
will also drain all moisture from the tanks.
4.
Clean the filter element and filter housing; replace the element if
necessary. Cover the entire unit to protect it from moisture and dust.
DISPOSAL
Recycle a tool damaged beyond repair at the appropriate facility.
TROUBLESHOOTING
Visit a Princess Auto Ltd. location for a solution if the tool does not
function properly or parts are missing. If unable to do so, have a
qualified technician service the tool.
PROBLEM(S)
Will not start
Low pressure
Motor is
overheating
12
4 Gallon Portable Quiet Air Compressor
POSSIBLE CAUSE(S)
Check power supply.
1. Safety valve leaks.
2. Drain cock is open.
3. Loose tubes or fittings.
4. Restricted air intake.
1. Clogged inlet filter.
2. Dirty compressor, head,
cylinder, intercooler.
3. Operating pressure too
high.
4. Compressor cycle too
long. Proper cycle is
50-60% on Stop/Start
operation.
SUGGESTED SOLUTION(S)
Make sure power is turned on.
1. Replace the safety valve.
2. Close drain cock.
3. Tighten or reseal leaking
fittings. Do not overtighten.
4. Clean or replace intake filter
element.
1. Clean or replace as
necessary.
2. Clean with compressed air.
3. Reduce operating pressure.
4. Allow for longer rest between
cycles.
For technical questions call 1-800-665-8685