Work
51
Current flow temp.
52
Heat generator 2
53
Status
54
Current flow temp.
55
HEATING 1
56
Status
57
Target flow temp.
58
Max limit outs.temp.
59
Heating curve
60
Minimum temperature
61
Maximum temperature
62
Auto Off mode
63
Cooling possible
64
Dew point monitoring
65
Min. cool. fl. tgt temp.
66
End OT cooling
67
Offset dew point
68
Pump status
69
ZONE1
70
Zone activated
71
Day temperature
72
Set-back temp.
73
Room temperature
74
Zone assignment
75
Zone valve status
76
Domestic hot water
77
Cylinder active
78
Target flow temp.
79
Domestic hot water
80
Current cyl. temp.
81
Cyl. charging pump
82
Circulation pump
83
Anti-legionella day
84
Anti-legionella time
85
Cyl. boost hysteresis
86
Cylinder boost offset
87
Max. cyl. charg. time
88
DHW req. anti-cy time
89
Ch. pump overrun time
90
Parallel cyl. charging
Menu → Installer level → Service information
91
92
Enter contact details
93
Service date Next service on
0020251825_01 System installation instructions
Commissioning checklist 3
Comments/settings
Current value display
Current value display (standby, heating, cooling, do-
mestic hot water)
Current value display
Current value display (off, heating mode, cooling, do-
mestic hot water)
Current value display
21 °C, change in consultation with the customer, if re-
quired
0.4 to 0.6 for underfloor heating
15 °C
45 °C for underfloor heating
Set-back
Yes for underfloor heating
No; you should not use passive cooling for compact col-
lectors and flat collectors
Yes
18 °C
15 °C
2 K
Current value display: off / On
Current value display: No / Yes
20 °C
15 °C
Current value display
VRC 700
Current value display (closed/open)
Condition: Domestic hot water cylinder in the system
Current value display
60 °C
Inform the end user about the anti-legionella function
Current value display
Current value display: off / On
Current value display: off / On
–
Select: off, Monday, Tuesday, Wednesday,
Thursday, Friday, Saturday, Sunday, Monday -
Sunday
–
Factory setting: off
04:00
5 K
25 K
45 min.
30 min.
5 minutes
off
Telephone number/company
Maintenance interval: 1 year
5