Specifications, Fuses and Circuit Breakers
Drive Ratings
Output Ratings
Catalog
Number
kW (HP)
100 - 120V AC (±10%) – 1-Phase Input, 0 - 230V 3-Phase Output
22A-V1P5N104 0.2 (0.25)
22A-V2P3N104 0.4 (0.5)
22A-V4P5N104 0.75 (1.0)
22A-V6P0N104 1.1 (1.5)
200 - 240V AC (±10%) – 1-Phase
22A-A1P4N103 0.2 (0.25)
22A-A2P1N103 0.4 (0.5)
22A-A3P6N103 0.75 (1.0)
22A-A6P8N103 1.5 (2.0)
22A-A9P6N103 2.2 (3.0)
200 - 240V AC (±10%) – 1-Phase
22A-A1P5N104 0.2 (0.25)
22A-A2P3N104 0.4 (0.5)
22A-A4P5N104 0.75 (1.0)
22A-A8P0N104 1.5 (2.0)
200 - 240V AC (±10%) – 3-Phase Input, 0 - 230V 3-Phase Output
22A-B1P5N104 0.2 (0.25)
22A-B2P3N104 0.4 (0.5)
22A-B4P5N104 0.75 (1.0)
22A-B8P0N104 1.5 (2.0)
22A-B012N104
2.2 (3.0)
22A-B017N104
3.7 (5.0)
380 - 480V AC (±10%) – 3-Phase Input, 0 - 460V 3-Phase Output
22A-D1P4N104 0.4 (0.5)
22A-D2P3N104 0.75 (1.0)
22A-D4P0N104 1.5 (2.0)
22A-D6P0N104 2.2 (3.0)
22A-D8P7N104 3.7 (5.0)
Input/Output Ratings
Output Frequency: 0-240 Hz (Programmable)
Efficiency: 97.5% (Typical)
Digital Control Inputs (Input Current = 6mA)
SRC (Source) Mode:
18-24V = ON
0-6V = OFF
Control Output (Programmable Output, form C relay)
Resistive Rating: 3.0A at 30V DC, 125V AC and 240V AC
Recommended Fuses and Circuit Breakers
Fuse: UL Class J, CC, T or Type BS88; 600V (550V) or equivalent. Circuit Breakers: HMCP or Bulletin 140U or equivalent.
Protective Features
Motor Protection: I 2 t overload protection - 150% for 60 Secs, 200% for 3 Secs (Provides Class 10 protection)
Overcurrent: 200% hardware limit, 300% instantaneous fault
Over Voltage:
100-120V AC Input – Trip occurs at 405V DC bus voltage (equivalent to 150V AC incoming line)
200-240V AC Input – Trip occurs at 405V DC bus voltage (equivalent to 290V AC incoming line)
380-460V AC Input – Trip occurs at 810V DC bus voltage (equivalent to 575V AC incoming line)
Under Voltage: 100-120V AC Input – Trip occurs at 210V DC bus voltage (equivalent to 75V AC incoming line)
200-240V AC Input – Trip occurs at 210V DC bus voltage (equivalent to 150V AC incoming line)
380-480V AC Input – Trip occurs at 390V DC bus voltage (equivalent to 275V AC incoming line)
Control Ride Through: Minimum ride through is 0.5 Secs - typical value 2 Secs
Faultless Power Ride Through: 100 milliseconds
Dynamic Braking
Internal brake IGBT included with all ratings except No Brake versions. Refer to Appendix B of the PowerFlex 4 User Manual
for DB resistor ordering information.
(1)
200-240V AC - 1-Phase drives are also available with an integral EMC filter. Catalog suffix changes from N103 to N113
and N104 to N114.
Input Ratings
Voltage
Amps
Range
kVA Amps Fuses
1.5
90-126
0.75 6.0
2.3
90-126
1.15 9.0
4.5
90-126
2.25 18.0
6.0
90-126
3.0
24.0
(1)
Input, 0 - 230V 3-Phase Output, NO BRAKE
1.4
180-265
0.7
3.2
2.1
180-265
1.05 5.3
3.6
180-265
1.8
9.2
6.8
180-265
3.4
14.2
9.6
180-265
4.8
19.6
(1)
Input, 0 - 230V 3-Phase Output
1.5
180-265
0.75 5.0
2.3
180-265
1.15 6.0
4.5
180-265
2.25 10.0
8.0
180-265
4.0
18.0
1.5
180-265
0.75 1.8
2.3
180-265
1.15 2.5
4.5
180-265
2.25 5.2
8.0
180-265
4.0
9.5
12.0
180-265
5.5
15.5
17.5
180-265
8.6
21.0
1.4
340-528
1.4
1.8
2.3
340-528
2.3
3.2
4.0
340-528
4.0
5.7
6.0
340-528
5.9
7.5
8.7
340-528
8.6
9.0
Approvals
Analog Control Inputs
SNK (Sink) Mode:
4-20mA Analog: 250 ohm input impedance
0-6V = ON
0-10V DC Analog: 100k ohm input impedance
18-24V = OFF
External Pot: 1-10k ohms, 2 Watt minimum
Branch Circuit Protection
140M Motor
Protectors
10
140M-C2E-C10 100-C09
15
140M-C2E-C16 100-C12
30
140M-D8E-C20 100-C23
40
140M-D8E-C25 100-C37
6
140M-C2E-B40 100-C09
10
140M-C2E-B63 100-C09
15
140M-C2E-C16 100-C12
25
140M-C2E-C16 100-C16
30
140M-D8E-C25 100-C23
10
140M-C2E-B63 100-C09
10
140M-C2E-B63 100-C09
15
140M-C2E-C16 100-C12
30
140M-D8E-C20 100-C23
3
140M-C2E-B25 100-C09
6
140M-C2E-B40 100-C09
10
140M-C2E-C10 100-C09
15
140M-C2E-C16 100-C12
25
140M-C2E-C16 100-C16
30
140M-F8E-C25 100-C23
3
140M-C2E-B25 100-C09
6
140M-C2E-B40 100-C09
10
140M-C2E-B63 100-C09
15
140M-C2E-C10 100-C09
15
140M-C2E-C16 100-C16
UL508C
U L
CSA 22.2
®
No. 14
C
US
Inductive Rating: 0.5A at 30V DC, 125V AC, and 240V AC
English-3
Power
Dissipation
IP20 Open
Contactors
Watts
32
40
55
80
32
40
55
85
125
32
40
55
85
32
40
55
85
125
180
35
50
70
100
150
EMC Directive 89/336/EEC, LV Dir. 73/23/EEC
LV:
EN 50178
EMC: EN 61800-3