For counters with a thickness of 40-50 mm,
install the clamps as shown below.
You must leave a ventilation opening on the
remaining part in order to provide ventila-
tion at the lower part of the hob. In addition
to being necessary for component tempera-
tures, this process is also compulsory for
the TC burner to take in air from the bottom.
2
It can be "100 cm
Flame must be blue and have a
regular shape. If the flame is
yellowish, check if the burner cap
is seated securely or clean the
burner.
Rear view (connection holes)
at least".
Place the burner plates, burner plate caps
and grills back to their seating after installa-
tion.
DANGER:
Making connections to different holes
is not a good practice in terms of
safety since it can damage the gas
and electrical system.
DANGER:
There are gas and electric compo-
nents on hobs. Therefore stove, only
the connection hole shown in this
manual should only be fixed to the
unit as shown in the manual using
the supplied fasteners and screws
supplied. Otherwise, it is dangerous
to the life and property safety.
Final check
1. Open gas supply.
2. Check gas installations for secure fitting
and tightness.
3. Ignite burners and check appearance of
the flame.
45/EN