Room ventilation
All rooms require an openable window, or
equivalent, and some rooms will require a
permanent vent as well.
The air for combustion is taken from the
room air and the exhaust gases are emitted
directly into the room.
Good room ventilation is essential for safe
operation of your appliance. If the room
where the appliance is installed does not
have a door or a window that opens directly
to the outer environment, there must defini-
tely be a fixed ventilation opening in the
room. The fixed ventilation must be nonad-
justable and non-closable.
On the doors or Windows that open directly
to the outer environment, there must be a
ventilation opening with the dimension
specified based on the total gaspower of
the appliance (as shown bellow) You can
find the gas power and ventilation opening
match-up in the table below.
Total gas consump-
tion (kW)
0-2
2-3
3-4
4-6
6-8
8-10
10-11,5
11,5-13
13-15,5
15,5-17
17-19
19-24
If the doors or windows that open directly to
the outer environment do not have ope-
nings corresponding to the ventilation ope-
ning specified according to the total gas
power of the product, there must definitely
be a fixed ventilation opening in the doom.
The fixed ventilation opening should also
be in compliance with the values in the gas
power-ventilation opening table. There
should be a minimum clearance of 10 mm
42/EN
.
Min. Ventilation
Opening (cm²)
100
120
175
300
400
500
600
700
800
900
1000
1250
on the bottom edge of the door-that opens
to the inner
environment- in the room where the product
is installed. You must make sure that items
such as carpets, floorings, etc. do not
cover this clearnace when the door is clo-
sed.
The cooker may be located in a kitchen,
kitchen/dinner or a bed-sitting room, but in
a room containing a bath or shower. The
cooker must not be installed in a bed-sitting
room of less than 20m³.
Do not install this appliance in a room be-
low ground level unless it open to ground
level on at least one side.
Installation and connection
The product must be installed in ac-
cordance with all local gas and electri-
cal regulations.
Electrical connection
Connect the product to a grounded out-
let/line protected by a fuse of suitable ca-
pacity as stated in the "Technical specifica-
tions" table. Have the grounding installation
made by a qualified electrician while using
the product with or without a transformer.
Our company shall not be liable for any
damages that will arise due to using the
product without a grounding installation in
accordance with the local regulations.
DANGER:
The product must be connected to
the mains supply only by an authori-
sed and qualified person. The pro-
duct's warranty period starts only
after correct installation.
Manufacturer shall not be held res-
ponsible for damages arising from
procedures carried out by unauthori-
sed persons.
DANGER:
The power cable must not be clam-
ped, bent or trapped or come into
contact with hot parts of the product.
A damaged power cable must be
replaced by a qualified electrician.
Otherwise, there is risk of electric
shock, short circuit or fire!