13.1
Shutdown in case of repair, emergencies and malfunctions
1.
To ensure that the device is disconnected from the power supply for repairs, switch it off using the main
switch and also pull out the power plug.
2.
To turn off the A/C service unit in an emergency or malfunction, turn off the main switch.
13.2

Short selection

A fully automatic air conditioning service is started using the Short selection menu. Included is a leak test that
must be carried out before working on the vehicle air conditioner. The vehicle air conditioner is filled with a sam-
ple refrigerant. The pressure in the vehicle air conditioner must remain constant over a period of 5 min. The vehi-
cle air conditioner can only be completely filled if this test has been successfully completed. The sample filling is
then drained and the vehicle air conditioner evacuated. The final filling quantity is completely filled up to ensure
high filling accuracy.You only have to enter the filling quantity as shown on the label in the vehicle.
The following actions are performed automatically in succession in the Short selection menu:
• Extraction of the refrigerant
• Recycling the refrigerant (purity = SAE J 2099)
• Pressure rise test
• Draining the used oil
• Evacuating the system
• Leak test/vacuum check
• Filling with new oil to the required quantity
• Filling with UV additive
• Filling of refrigerant
After each process has been performed a service report is printed. Subsequent actions are only initiated once the
preceding action has been completed successfully.
1.
Fit the service hoses for the A/C service unit to the vehicle air conditioning system, and open the service
couplings.
2.
Press the cursor key
3.
In the basic menu use the cursor keys
Short selection
Free selection
Other selections
ENTER-OK
4.
Press ENTER to confirm.
5.
Use the keypad and the cursor keys to enter the vehicle data.
6.
Press ENTER to confirm.
7.
Enter the refrigerant filling quantity. Use the value shown on the filling quantities sticker in the vehicle and
enter it using the keypad and the cursor keys and press ENTER.
8.
Use the cursor keys
sure and low pressure) or only one connection (high pressure or low pressure).
HP/LP
HP
LP
ENTER-OK STOP-EXIT
Press ENTER to confirm.
9.
The fully automatic air conditioning service is started.
After the air conditioning service has finished, you will be prompted to disconnect the A/C service unit's ser-
vice hoses of from the vehicle air conditioning system.
10. Disconnect the service hoses and press ENTER to confirm.
The service hoses will now be drained. The A/C service unit is then ready for further use.
11. Put the valve caps of the vehicle air conditioning system back on the connections.
16