Télécharger Imprimer la page

Waeco AirCom Service 6300G Manuel D'utilisation page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 53
2.
Press ENTER to confirm.
The chosen refrigerant is displayed.
Confirm
Refrigerant
R-513A
ENTER-OK
3.
Press ENTER to confirm the selection and follow the instructions in the display and provided here:
Please install HP/LP
connection hose!
Once done, press OK.
ENTER-OK
4.
Install the HP/LP connection hoses.
Press ENTER to confirm.
5.
Wait !
The service hoses are evacuated.
6.
Wait until the service hoses are evacuated.
7.
Press ENTER to confirm the displayed refrigerant:
WARNING !
Usage only with
R - 513A
!
ENTER-OK
The A/C service unit runs a cleaning phase of the internal vessel pressure.
Cleaning phase.
Internal vessel
pressure
mb.
Afterwards the A/C service unit runs a software test.
Please wait!
Software test.
Don't connect to
the A/C system yet!
Afterwards the A/C service unit displays the Standby menu:
Refrigerant
PAG oil
UV tracer
11:56:35
Yes
No
g.
XXXX
ml
XXX
ml
XXX
10/03/17
English
9

Publicité

loading

Ce manuel est également adapté pour:

Aircom service 6400g