Reassembly (Fig. 15)
After cleaning and inspecting all parts, reassemble the filter.
1. Place the carbide seat (6) into the filter body (4). Make sure
the beveled side of the seat is facing up.
2. Place the PTFE o-ring (5) into the groove on the outer
diameter of the carbide seat (6).
3. Place the filter element with ball (3) into the filter body (4).
i
The top and bottom of the filter element with ball
are identical.
4. Push the spring (2) back onto the spring guide of the filter cap
(1) until it "snaps" back into position, if not already done.
5. Place the thin PTFE gasket (8) onto the step at the top of the
filter body (4).
6. Place the thick PTFE gasket (7) onto the top of the thin gasket
(8).
7. Tighten the filter cap assembly (1) onto the filter body (4).
1
2
3
5
6
4
7
8