Care And Maintenance Instructions; Before Each Wear; Every 6 Months; Leak Test - Mustang Survival M.I.T. 70 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CARE AND MAINTENANCE
To ensure your flotation device performs when you need it, you must
care for and maintain it in serviceable condition (see "Mandatory
Carriage Requirements," page 3). Failure to follow these instructions
rigorously could result in a non-functioning flotation device causing
injury or death. We suggest you keep a record of the inspections
performed on your flotation device – using permanent ink on the
Care and Storage label below the oral inflation tube. If you are not
confident that you can care for and maintain your flotation device, or
if you are in doubt about these instructions, contact Mustang Survival
customer service.
You are required to check this flotation device:
• Before each wear (component inspection)
• Every six months (leak test and thorough visual examination)
• After each inflation (perform re-arm)
• Annually (suggested at the beginning of each boating season)

BEFORE EACH WEAR

See "Inspecting Components," page 4, for instructions. If you see any
signs of damage, perform the "Every Six Months" tests below.
EVERY SIX MONTHS
The following tests are suggested every six months at minimum or
whenever you see signs of damage to your flotation device. Perform
these tests more often if the flotation device is exposed to potential
damage or used in extreme conditions.

• Leak Test

Orally inflate your flotation device until firm and let stand six hours
minimum. As long as your flotation device has been inflated orally
(not by CO
cylinder ) it should hold its firmness for this length of
2
time. If this is not the case, your flotation device is leaking and should
be replaced. If your flotation device leaks, contact Mustang Survival
customer service.

• Thorough Visual Examination

See "Inspecting Components," page 4.