SubDrive Solar Specifications

Absolute maximum input voltages
PV, DC
Back-up generator
NOTE: Suitable for use on a photovoltaic circuit capable of delivering not more than 50 DC amps
short circuit current, or on a back-up AC generator capable of delivering not more than 5000
amps symmetrical rms current.
Controller Model No.
Output
Output voltage, max
Max Amps (RMS)
Output Frequency
Efficiency at Max Power
PV source
Input Voltage, at mpp
Max Amps Input
Power at mpp
Alternate AC Generator
Input voltage
Max Amps (RMS)
Power and VA capability
Controller Size
Centimeters
Inches
Operating Conditions
Temperature Range
Relative Humidity Range
*The 0.55 kW drive will attempt to start the pump/motor with input voltage as low as 95 V, and attempt to continue to
run the pump/motor as low as 75 V input voltage. However, 75 Vdc should not be interpreted as an adequate rated PV
array output voltage for any installation. The recommended Vmpp minimum for the system's solar PV array is 110 Vmpp.
Maximum open-circuit voltage input to the controller is 410 Voc. See the PV Solar Array Specifications and System Sizing
program for indication of adequate array voltage to provide useful pumping capability.
**The 1.1 and 2.2 kW Drive will attempt to start the pump/motor at 190 V DC, and attempt to continue operation down to
150 V DC. The recommended Vmpp minimum for the system's solar PV array is 225 Vmpp. Maximum open circuit voltage
input to the controller is 410 Voc.
410 V, open circuit
260 VAC, rms
0.55 kW model*
5870300553
100 V AC, 3-phase
8.6 A, each phase
30-60 Hz
96%
95 – 330 V DC
8.7 A DC, continuous
Up to 1400 Watts
230 V AC, single-phase
9.7 A DC, continuous
Follow Instruction Manual
for proper Generator
Sizing Data
53.34 X 25.87 X 21.87 cm
21.00" X 10.19" X 8.61"
-25 °C to 50 °C (40 °C max
when using AC generator)
-13 °F to 122 °F (104 °F max
when using AC generator)
0 to 100% Condensing
Table 7: SubDrive Solar Drive Specifications
1.1 kW model**
5870301113
200 V AC, 3-phase
6.8 A, each phase
30-58 Hz
96%
190 – 330 V DC
7 A DC, continuous
Up to 2000 Watts
230 V AC, single-phase
16 A
Follow Instruction Manual
for proper Generator
Sizing Data
L X W X D
53.34 X 25.87 X 21.87 cm
21.00" X 10.19" X 8.61"
-25 °C to 50 °C (40 °C max
when using AC generator)
-13 °F to 122 °F (104 °F max
when using AC generator)
0 to 100% Condensing
2.2 kW model**
5870301223
200 V AC, 3-phase
12.5 A, each phase
30-68 Hz
96%
190 – 330 V DC
12 A DC, continuous
2000 – 3500 Watts
230 V AC, single-phase
25 A
Follow Instruction Manual
for proper Generator
Sizing Data
L X W X D
53.34 X 25.87 X 26.31 cm
21.00" X 10.19" X 10.36"
-25 °C to 50 °C (40 °C max
when using AC generator)
-13 °F to 122 °F (104 °F max
when using AC generator)
0 to 100% Condensing