GETTING STARTED
This owner's manual provides you with the information required
to safely own and operate your flow control switch. Retain these
instructions for future reference.
This flow control switch is of the highest quality workmanship and
material. It has been engineered to give you long and reliable service.
Our products are carefully tested, inspected, and packaged, ensuring
safe delivery and operation.
Inspect Your Shipment
Please examine your product carefully to ensure that no damage
occurred during shipment. If damage is evident, please contact the
place of purchase or report this immediately to your shipping carrier.
They will assist you in replacement or repair, if required. In the case
of shipping damage, the carrier is fully responsible for the product's
safe arrival. Any claim for damage to the shipment, either visible or
concealed, must be made through the shipping carrier.
Package Includes:
• Pump control device
• Booster pump (in certain models)
• Installation manual
SPECIFICATIONS
Name
Description
Weight
(on label)
Inline Pump
Inline SWC
2 lbs.
Pressure Control
Inline Pump
Inline SWP
3 lbs.
Pressure Plus
Inline Pump
Pressure Adjust
Inline ADJ
2 lbs.
(115 V)
Inline Pump
Pressure Adjust
Inline ADJ
2 lbs.
(230 V)
All Inline Pumps are Type 4 NEMA Enclosure Rated.
4
Max.
Max. Motor Size
V
Current
0.75 hp 0.55 kW
115
16 A
2.0 hp
1.5 kW
230
1.0 hp
0.75 kW
115
20 A
3.0 hp
2.2 kW
230
0.75 hp 0.55 kW
115
16 A
2 hp
1.5 kW
230
16 A
DANGER
fluids such as gasoline, fuel, oil, kerosene, etc. Do not use in explosive
atmospheres. Pump should only be used with liquids compatible with
pump component materials.
DESCRIPTION
This device activates your pump as water is used in the building. Once
the flow stops, the pump turns off. This will protect your pump in
case of a water shortage or dry run event. This product uses either 115
volts or 230 volts and can be installed on any surface-mounted pump.
When using this device, a pressure tank is not required, but can be
used as an optional accessory.
Min.
Electrical
Plumbing
Operating
Flow
Connection
Connection
Pressure
gpm
FNPT
FNPT
psi (bar)
0.26
1/2"
1"
174 (12)
0.26
1/2"
1-1/4"
174 (12)
0.26
1/2"
1"
174 (12)
0.26
1/2"
1"
174 (12)
Do not use to pump flammable or explosive
Hazardous Pressure
Booster pumps can produce significant
water pressure within a plumbing system.
This could cause damage to pipes and/or
fixtures. To prevent personal or property
damage, install a pressure relief valve
capable of conveying entire water volume
to a drain. Relieve system pressure before
disassembling the device.
Max.
Max.
Protection
Operating
of Internal
Temperature
Components
Pollution
131 °F (55 °C)
Degree 2
Pollution
131 °F (55 °C)
Degree 2
Pollution
131 °F (55 °C)
Degree 2
Pollution
131 °F (55 °C)
Degree 2
Nominal
Impulse
Fluid
Voltage
Temperature
2.5 kV
68 °F (20 °C)
2.5 kV
68 °F (20 °C)
2.5 kV
68 °F (20 °C)
2.5 kV
68 °F (20 °C)