Installation
The floating switch can be installed as follows:
•
The floating switch can be inserted into the tank – through a tapped hole G1A – and screwed to
the compression gland (G1A).
•
If it is installed from above, use the weight.
Note!
•
The fulcrum of the cable should always be horizontal.
•
The cable length between the fixture and the floating body is dependent on the cable type
(see "Technical data").
•
When using the weight, place an extra strain relief (e.g. a knot in the cable) behind the com-
pression gland – on the outside of the tank.
E
..
6
Endress + Hauser