ASCON TECNOLOGIC X34 Mode D'emploi page 22

Table des Matières

Publicité

on
=
on
instrument switch on
HE= Heating (Neutral
zone control)
2d = Defrosting 2
L1
=
light
economy
mode
with "SP" and off with
"SPE")
L2 = internal light (off
with door closed and
on with door opened)
82
o.o2 OUT2 function:
see "o.o1"
83
o.o3 OUT3 function:
see "o.o1"
84
o.o4 OUT4 function:
see "o.o1"
85 o.bu Buzzer function mode
oF = disable
1 = active alarms only
2 = key pressed only
3 = active alarms and
key pressed
86 o.Fo Function
auxiliary output:
oF= No Function
1= control output "ot"
delayed
2= manual activation
by key or digital input.
87
o.tu Time
relative
auxiliary output
]tS
t. -parameters relative to configuration of the
keyboard and serial communication
88
t.UF Function mode key U:
oF= No function
1=
Auxiliary
command
2= Norm. / Eco mode
Selection
3=
Switch
(Stand-by)
4=
"Turbo"
command
5 = Manual Switch
on/off (Stand-by) when
set by clock
6=
HACCP
Reset
7= HACCP Alarms rec.
disable/enable
89
t.Fb Function
mode
Down/Aux: see "t.UF"
90
t.Lo Keyboard lock function
delay
91
t.Ed Set Visibility with fast
procedure by key P:
oF = None
1 = SP
ASCON TECNOLOGIC - X34- -OPERATING INSTRUCTIONS - Vr. 02 - 11/12 - ISTR-MX34FRA02 - PAG. 22
when
with
(on
oF/ot/dF/
Fn/Au/At/
AL/An/ -t/ -L/ -
n/on/HE/2d/
L1/L2
oF/ot/dF/
Fn/Au/At/
AL/An/ -t/ -L/ -
n/on/HE/2d/
L1/L2
oF/ot/dF/
Fn/Au/At/
AL/An/ -t/ -L/ -
n/on/HE/2d/
L1/L2
oF / 1 / 2 / 3
mode
oF / 1 / 2
to
oF/ 0.01 ÷ 9.59
(min.sec ) ÷
99.5
(min.sec.x10)
oF / 1 / 2 / 3 / 4
/ 5 / 6 / 7
output
on/off
cycle
Alarms
key
oF / 1 / 2 / 3 / 4
/ 5 / 6 / 7
oF/ 0.01 ÷ 9.59
(min.sec ) ÷
30.0
(min.sec.x10)
oF / 1 / 2 / 3 / 5
/ 6
92
t.PP Access Password to
93
t.HA
(#)
dF
94
t.AS MODBUS
]cL
Fn
95 c.CL
(#)
Au
96
c.dt
3
(#)
]cE
97
c.01
oF
(#)
oF
oF
98
c.02
(#)
99
c.03
(#)
100 c.04
oF
(#)
101 c.05
oF
(#)
102 c.06
(#)
4
103 c.07
(#)
104 c.08
(#)
2 = SPE
3 = SP e SPE
4 = Active SP
5 = SP and SPH
6 = SP, SPE and SPH
parameter functions
HACCP
Alarms
Parameters level
1
=
protected
parameters
2
=
unprotected
parameters
Station
address
(for
serial
communication)
c. - parameters relative to clock setting
Current
time
and
current
day
of
the
week:
d. = oF-1 ÷ 7
h = hour
n = min.
d = day of the week
(d.1 = Monday ... d.7 =
Sunday)
d.oF = clock disable
Current date:
y. = 10 ÷ 99
y = year
M = month
d. = 1 ÷ 31
d = date
c. parameters relative to events occour at defined
times
Event 1
h = hour
n = min.
d. = oF-1 ÷ 11
d = day of the week
t. = oF-1 ÷ 10
(d.1 = Monday ... d.7 =
Sunday
d. 8 = every day
d. 9 = from Monday to
Friday
d.10 = from Monday to
Saturday
d.11 = Sat. and Sun.
d.oF = no day (event
disabled)
t = event type
t.1 = Switch on
t.2 = Stand-by
t.3 = Switch on Aux
output
t.4 = Switch off Aux
output
t.5 = Start defrost
t.6 = Switch to Eco
mode (SPE)
t.7 = Switch to normal
mode (SP)
Event 2
Event 3
Event 4
Event 5
Event 6
Event 7
Event 8
oF ÷ 999
oF
1 / 2
1
0 ÷ 255
1
h. = 0 ÷ 23
n. = 0 ÷ 59
n. = 1 ÷ 12
h. = 0 ÷ 23
h.0
n. = 0 ÷ 50
n.0
d.oF
t.oF