Produktgruppe 512
20 von 22
am
Parts required
Quantity
Mat. no.
1
09079480
Note
This service and repair work should only be carried out by a suitably qualified electrician (with specialist training, knowledge and
experience, and recent related work experience) in accordance with all appropriate local and national safety regulations.
Commissioning, servicing, modification, testing and maintenance of electrical appliances should only be carried out in accordance with
all appropriate legal requirements, accident prevention regulations and valid standards. All regulations of the appropriate utility supply
companies and standards relating to safety (not limited to electrical safety) are to be complied with.
Danger!
Even with the machine switched off, voltage may be applied to some components.
Before starting any service work, the machine must be disconnected from the power supply. Suitable measurements must be made to
ensure that this is the case.
A general visual check and risk evaluation should always be carried out. Incorrect conversion or service work can be dangerous (risk of
fire, electric shock, etc.).
Danger!
Correct grounding function can be deactivated if casing parts are incorrectly assembled.
Correct grounding function must be ensured when reassembling the casing.
Carry out appropriate electrical safety checks.
Danger!
During installation, all accessible conductive parts that are not connected to ground must not have any link to ground (strengthened
double insulation).
To confirm this, insulation resistance and touch current measurements must be carried out.
Note
This installation kit contains:
1 EZL 235 electronic
4 spacers
1 coded plug MFM 1-4-5 (module 7EZL 235
1 wiring harness 20X-41X (module 7 EZL 235
1 wiring harness 51X-52X-3X3/4 (module 7 EZL 235
1 wiring harness N1Q_ST112, N1Q_ST11 (module 7EZL 235
2 screws, 2.9x9.5
1 wiring diagram for PW 6107 PW 6207 module 7, mat. no. 09021430
These instructions.
List of illustrations:
Fig. 1, EZL 235 electronic installation
Fig. 2, EZL 235 / ELP 235 wiring, module 7 flow meter (impeller)
Fig. 3, EZL 235 / EZL 235 wiring, module 7 flow meter (impeller)
10.06.2011
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Designation
MF07 10 20 multifunction module PWxx7 installation kit
ST3), pin 1-4-5
ST10), 3-pin, 500 mm
ST12, ST13), three 3-pin plugs, approx. 830 mm
ST111), 4-pin, 350 mm
Umbau- und Montageanweisung
M.-Nr. 09087190