Operating Instructions

Unpacking

Do not lift or move unit without appropriately rated equipment. Be sure
the unit is securely attached to lifting device used. Do not lift unit by
holding onto tubes or coolers. Do not use unit to lift other attached equipment.
After unpacking the unit, inspect carefully for any damage that may have occurred
during transit� Check for loose, missing or damaged parts� Check to be sure all supplied
accessories are enclosed with the unit� In case of questions, damaged or missing parts,
please call 1-888-606-5587 for customer assistance�
Do not operate unit if damaged during shipping, handling or use.
Damage may result in bursting and cause injury or property damage.
required iTeMS - noT inCluded
Oil
Vibration Isolator Pads (Shop Air Series only)

Installation

Disconnect, tag and lock out power source then release all
pressure from the system before attempting to install, service,
relocate or perform any maintenance.
Do not lift or move unit without appropriately rated
equipment. Be sure the unit is securely attached to lifting
device used. Do not lift unit by holding onto tubes or coolers. Do not use unit to lift other
attached equipment.
Never use the wood shipping skids for mounting the compressor.
piCkinG THe loCATion
Install and operate unit at least 18 inches from any obstructions in a clean, well
ventilated area� The surrounding air temperature should not exceed 100° F� This will
ensure an unobstructed flow of air to cool compressor and allow adequate space for
maintenance�
Do not locate the compressor air inlet near steam, paint spray, sandblast
areas or any other source of contamination.
NOTE: If compressor operates in a hot, moist environment, supply compressor pump
with clean, dry outside air� Supply air should be piped in from external sources�
TAnk MounTinG
The tank should be bolted into a flat, even, concrete floor or on a separate concrete
foundation. Vibration isolators should be used between the tank leg and the floor.
Model MP345800AJ isolator pads are recommended for horizontal units� Model
MP345700AJ isolator pads are recommended for vertical units� Isolator pads are
included with fully packaged models�
When using isolator pads, do not draw bolts tight. Allow the pads to absorb vibrations�
When isolators are used, a flexible hose or coupling should be installed between the
tank and service piping�
Failure to properly install the tank can lead to cracks at the
welded joints and possible bursting.