3.6 Support leg
On an even working surface, the support leg makes it easier to hold the fastening tool perpendicular as
attention then only has to be paid to lateral alignment. On an uneven or undulating surface it may be necessary
to remove the support leg in order to allow the fastener guide to be held perpendicular to the working surface.
3.7 Belt hook
The belt hook can be extended in three stages.
Status
Position 1
Position 2
Position 3
3.8 Gas can
Note
Observe the safety instructions provided with the gas can!
In order to operate the fastening tool, the gas can must be inserted in the gas can compartment.
The gas can status can be read from the LED display after pressing the GAS button.
The gas can must be removed before breaks between working, before maintenance and before transporting
or storing the fastening tool.
3.9 Indication of gas can status
After pressing the GAS button, the LED display indicates the status of the gas can.
Status
All four LEDs light green.
Three LEDs light green.
Two LEDs light green.
One LED lights green.
One LED blinks green.
One LED blinks green.
One LED blinks red.
3.10 Indication of battery charge status
After pressing a battery release button, the display shows the status of the battery and the fastening tool.
Status
All four LEDs light green.
Three LEDs light green.
Two LEDs light green.
One LED lights green.
One LED blinks green.
One LED blinks green.
Printed: 11.09.2017 | Doc-Nr: PUB / 5373611 / 000 / 00
Meaning
•
Position for attaching to a waist belt
•
Position for attaching to ladders, scaffolds,
platforms, etc.
•
Belt hook removed
Meaning
•
The level is between 100 % and 75 %.
•
The level is between 75 % and 50 %.
•
The level is between 50 % and 25 %.
•
The level is between 25 % and 10 %.
•
Level is below 10 %. Replacement of the gas
can is recommended.
•
The gas can is empty or is malfunctioning.
Replacement of the gas can is recommended.
Note
Even when the level is indicated as "empty", the
gas can, for technical reasons, still contains a little
gas.
•
No gas can or the wrong type of gas can is
present in the fastening tool.
Meaning
•
Charge status is 75 % to 100 %.
•
Charge status is 50 % to 75 %.
•
Charge status is 25 % to 50 %.
•
Charge status is 10 % to 25 %.
•
Charge status is below 10 %. The fastening tool
is ready for operation.
•
The fastening tool is overloaded or overheated
and thus not ready for operation.
English
5