Installation instructions, only for experts

5.4. F1 heater sensor

1. Guide the wires for the heater sensor through the cable gland 2 into the
low-voltage connection area.
2. Connect the red wires for the heater sensor to the terminals labelled "STB"
in terminal strip c.
3. Connect the white wires for the heater sensor to the terminals labelled "F1"
in terminal strip c.

5.5. Bench sensor F2 (optional)

1. Feed the wires for the bench sensor through the cable gland 2 into the
low-voltage connection area.
2. Connect the wires for the bench sensor to the terminals labelled "F2" in
terminal strip c.

5.6. Humidity temperature sensor FTS2 (optional)

1. Feed the wires for the sensor through the cable gland 1 into the low-volt-
age connection area.
2. Connect the wires for the temperature sensor to the terminals labelled "F2"
in terminal strip c.
a. Connect the black wire to the right terminal.
b. Connect the brown wire to the left terminal.
3. Connect the wires for the humidity sensor to the terminals labelled "FTS2"
in terminal strip c.
c. Connect the green wire to the terminal "GREEN".
d. Connect the orange wire to the terminal "ORANGE".
e. Connect the red wire to the terminal "RED".
p. 22/64