Instructions for use for the user
10.4. Combi-mode
Starting combi-mode
1. Use rotary selector 1 to select the temperature icon. Then press
it briefly to confirm.
► The "Humidity" submenu opens and the setpoint value for the hu-
midity appears underlined in the display.
2. Press the rotary selector to change the value.
► The value is now highlighted in green and can be changed.
► Press the rotary selector again to confirm the setting.
3. Move the cursor (underscore) to the right to "On" and briefly press
the rotary selector.
► The vaporizer is switched on and begins to heat up.
► The colour of the humidity icon in the notification area changes
to blue.
► You automatically exit the "Humidity" menu item.
Switching off combi-mode
4. To switch off the vaporizer, repeat points 1 and 3.
► Instead of "On", "Off" is displayed.
► To exit the submenu, move the cursor to the "Back" icon on the
left and confirm with the rotary selector.
► The vaporizer switches off.
The vaporizer can only be started when the sauna heater is switched on.
The maximum humidity level which can be set depends on the temperature
of the sauna. The higher the sauna temperature, the lower the maximum
humidity level which can be set (see characteristic curve).
Exception: Vaporizer single mode is activated (see "9.1. Technician
menu" on page 33). The vaporizer can also be operated here without
the sauna heater, with the maximum humidity depending on the current
sauna room temperature.
p. 38/64