Laser classification

The power tool conforms to a class 2, laser based on the standard
IEC 825-1/EN 60825. Eyes must be protected with the eyelid close
reflex in case you accidentally glance into the laser beam. However,
this eyelid protective reflex may be impaired by medication, alcohol or
drugs. These devices may be used without taking any further
precautionary measures provided that there are no optical instruments
which can reduce the cross-section of the beam. Do not aim the laser
beam at people.

Electromagnetic compatibility

Although the power tool satisfies the strict requirements specified in
the relevant directives, it cannot be excluded that the power tool
– will affect other power tools (e.g. navigation equipment on aircraft) or
– itself will be affected by high radiation, resulting in a malfunction.
In these or other uncertain cases, check measurements should be
taken.

Intended use

This point laser is designed for use in industry and trade.
The power tool is designed to determine, transfer and check horizontal
courses, vertical lines, perpendicular points and right angles, e.g.:
– to transfer metre and height cracks,
– to mark partition walls (vertical and/or at a right angle) and
– to align equipment and controls in three dimensions.

Safety instructions

Warning!
– Keep children away from laser power tools.
– Use suitable measures to prevent a third party from looking into the
laser beam with optical instruments.
– If at all possible let the laser beam path run above or below eye
level.
– It is not permitted to tamper with or change the power tool. Do not
disable safety devices and do not remove information and warning
signs.
– Before switching on the power tool, check for visible damage.
Do not switch on damaged power tools.
– The power tool may be repaired by authorised technicians only.
If the power tool is opened without authorisation, laser radiation
may be emitted which exceeds class 2.
– Do not use the power tool in an explosive environment.
– If carrying out alignment work on ladders, avoid an abnormal
posture. Ensure that you have a secure footing and keep your