Nefl42 / 50 / 60 / 74 Chd 120V Hardwiring - Napoleon Alluravision Serie Manuel D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.5.2 NEFL42 / 50 / 60 / 74 CHD 120V hardwiring

note:
There are 5 wires from the appliance junction that connect to 120V power supply (breaker panel): 1 white (neu-
tral), 2 yellow (heater & neutral), 1 black (power L1), and 1 green (ground). Do NOT connect red wire to power
supply (breaker panel).
1. Remove the securing screws from the electrical cover plate located on the rear left side of the appliance.
2. Loosen the securing screws from the terminal block to remove the cord from the terminal block.
3. KEEP 2 JUMPER WIRES IN THE TERMINAL BLOCK.
4. Add an electrical box connector and feed the supply wires through the 7/8" (22mm) hole from the terminal
block.
5. Insert White (N) wire from power supply to the designated (N) slots in the terminal block. Secure by tightening
the screws on the (N) slots. ENSURE JUMPER WIRES ARE SECURED.
6. Repeat step 5 with Black (L1) and Green (G), securing them to their designated slots in the terminal block.
7. Re-install cover plate.
note:
Leave enough wire so that the appliance can be removed from the enclosure for ease of disconnecting the
power supply if the appliance needs to be serviced.
Use 2 jumper wires
to connect
N to N1 and N2.
WHITE (N)
YELLOW (N1)
YELLOW (N2)
BLACK (L1)
RED (L2)
GREEN (G)
W
WHITE (N)
YELLOW (N1)
L
YELLOW (N2)
L
BLACK (L1)
L
RED (L2)
R
GREEN (G)
120V
JUMPER
WHITE (N)
JUMPER
BLACK (L1)
GREEN (G)
installation
EN
(N)
Jumper
Jumper
(L1)
(G)
17
W415-2212 / F / 04.23.19

Publicité

Chapitres

Table des Matières
loading

Table des Matières