it is hooked securely.
Settlement of outdoor unit
Anchor the outdoor unit with a bolt and nut 10 or 8 tightly and horizontally on a concrete or rigid mount.
Drain joint installation
Fit the seal into the drain elbow, then insert the drain joint into the base pan hole of outdoor unit, rotate 90 to securely
assemble them. Connecting the drain joint with an extension drain hose (Locally purchased), in case of the water draining off
the outdoor unit during the heating mode.
Piping and wrapping
Bundle the tubing, connecting cable, and drain hose with tape securely.
● Because the condensed water from rear of the indoor unit is gathered in pending box and is piped out of room. Do not put
anything else in the box.
CAUTION
● Connect the indoor unit first, then the outdoor unit.
● Do not allow the piping to let out from the back of the indoor unit.
● Be careful not to let the drain hose slack.
● Heat insulated both of the auxiliary piping.
● Be sure that the drain hose is located at the lowest side of the bundle.
Locating at the upper side can cause drain pan to over flow inside the unit.
● Never intercross nor intertwist the power wire with any other wiring.
● Run the drain hose sloped downward to drain out the condensed water
smoothly.
● The power cables should not come into contact with the tubing.
Model
Connective pipe length max
(W)
without additional refrigerant (m)
2500W
3200W
4600W
6155W
Wiring connections
Connect the cable to the indoor unit
1. Indoor/Outdoor connection cable should be H07RN-F type.
2. Lift the indoor unit panel up and remove the screw, then remove the window cover
3. Connect cables according to their marks to terminals.
4. Wrap those cables not connected with terminals with insulation tapes, so that they will
not touch any electrical components.
Allowed connective
pipe length (m)
5
5
5
5
indoor unit
Max. difference
in level (m)
15
10
20
10
20
10
25
10
indoor and outdoor
connection wires
gas pipe
with isulation
band
drain hose
Additional amount of
ΦLiquid/Φgas
refrigerant (g/m)
Φ6,35/Φ9,52
16
Φ6,35/Φ9,52
16
Φ6,35/Φ12
16
Φ6,35/Φ16
40
Front panel
Indoor unit
liquid pipe
with isulation
Terminal
36