Sapporo
English
To protect hands during this operation, wear working gloves.
17. Dismantling the cabinet
In accordance with the waste disposal regulations in each country and in respect of the environment
in which we live, please differentiate the parts of the cabinet so as to be able to dispose of them
separately or recycle them appropriately.
None of the parts that make up the cabinet can be disposed of together with urban solid waste, except
for the metallic components, which, in any case, are not classified as special waste in most European
countries.
Materials used in the manufacture of the cabinet:
- Stainless steel 18/10 (AISI 304):basic structure of cabinet
- Iron pipe:
- Copper, Aluminium:
- Galvanized steel sheet:
- Foam polystyrene (R134a):
- Tempered glass:
- PVC:
- Wood:
This product contains HFC, a refrigerating gas with a high Global Warming Potential (GWP).
ARNEG equips its cabinets with refrigeration units incorporating the following types of refrigerating
gasses:
R 134a; GWP
(100)
R 404A; GWP
(100)
in the family of the HFCs, which are fluoridated gasses with a high global warming potential (GWP),
regulated by the Kyoto protocol (check on the rating plate or adhesive label on the compressor which
of these two gasses is used in the unit).
Therefore:
THE COMPONENTS OF THE REFRIGERATING CIRCUIT MUST NOT BE CUT OR SEPARATED,
BUT MUST BE TAKEN INTACT TO CENTRES SPECIALISED IN RECYCLING REFRIGERATING
GAS.
This unit is hermetically sealed and the refrigerating gas load is under 3 kg.
For this reason it is not subject to the requisite of an installation booklet and periodic
inspections for leakage of the refrigerating gas (Presidential Decree no. 147 of February 15, 2006
Art. 3 and 4).
18. Useful suggestions
Please read the Installation and Use Manual carefully; in this way, our telephone operator will be
able to provide more precise indications as to the Technical Assistance required in the event of
operating problems.
Before carrying out any maintenance operation on a refrigerating cabinet, make sure that it
has been unplugged.
Should the client detect any failure in the cabinet operation, check the points below before
calling the Technical Service:
- Check that the ambient temperature and humidity values do not exceed the ones indicated.
For this reason, the air conditioning, ventilation and heating devices in the shop should always be
kept at full efficiency.
- Limit the speed of the ambient air to values lower than 0.2 m/s near the cabinet openings; in particu-
lar, it is also necessary to prevent air streams and air intakes from being directed toward the cabinet
openings.
- Make sure that the goods displayed are not exposed to direct sunlight.
- Limit the temperature of radiating surfaces in the shop, e.g. by insulating the ceilings.
- Do not use spotlights with incandescent lamps directly oriented towards the cabinet.
- Only use the cabinet for items previously refrigerated to the temperature that normally characterises
the chain of cold.
- Make sure that the cabinet is always capable of maintaining such a temperature.
- Respect the loading limit and never overload the cabinet.
26
lower frame
refrigerating circuit, electric system
lower frame, grids
thermal insulation
front and sides
all the parts in plastic
foamed tray side frames
= 1300
= 3750