Ballast side.
FMD 16 x16 A
HARTING
DESIGNATION
REP
1
Fan phase.
2
Ballast phase.
3
Lamp Neutral.
4
5
6
Security return 1200.
7
Security return 2500.
8
Security not used.
Note: This is a universal cable and is suitable for a follow spot
or a profile, 1200W. or 2500W.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
2500W HMI FOLLOWSPOT
CONNECTION
g
a
b c
DATA Link.
a & f
Flexible cable
FF XLR 5.
5 x 0,14 shielded
CN5.
DESIGNATION
REP
1
0V.
2
DATA - IN.
3
DATA + IN.
4
5
Lamp cable.
Delivered standard : 3m.
Cable H07 RN-F
2
18G 1,5mm
DESIGNATION
REP
9
Ignition timed phase.
10
Ballast phase.
11
Lamp Neutral.
12
Earth.
13
Aux. phase.
14
Aux. Neutral.
15
Common security.
16
Earth.
Female side earth only.
h
b,c & d
Flexible cable
FM XLR 5.
5 x 0,14 shielded
CN5.
DESIGNATION
REP
1
0V.
2
DATA - OUT.
3
DATA + OUT.
4
5
h
Lighting unit side.
FFD 16 x16 A
HARTING
1013
1013
B, BS, M & BSM
B / BS
Section A - 17
f e
d
e
Flexible cable
FF XLR 4.
4 x 0,14 shielded
CN5
DESIGNATION
REP
1
0V.
2
3
0/+10V. Shutter
4
+15V.
+
+
/
/