Les langues disponibles

CONNECTIONS.
f
Mains voltage.
- Check the conformity of the mains voltage input with the values indicated
on the identification plate of the PSU (mains voltage & lamp power)
Lighting unit / Power supply connection.
- Connect the lighting unit's power cable B by passing it
inside the yoke.
- Leave a little slack and then block the cable B into the lock j .
- Place the lamp into position - refer to section A - 11.
- Connect the cable O to the mains.
WARNING !
- Never open the lamp house's bonnet when the lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when lamp in place.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr
2500W HMI FOLLOWSPOT
A
i
e
g
h
j
TECHNICAL FILE
D
B
o
• Use only the listed cables to connect to the mains -
Refer to the respective PSU technical fi le.
DESCRIPTION.
A 1013+ M / (*)BSM - Motorised shutter version.
e - EM HARTING 6 x 35A. power socket.
*f - EM XLR 4 output 0/+10V. (extra)
*g - EM XLR 5 input DATA.
*h - EF XLR 5 output DATA.
*i - Fuse (10,3 x 38 - 2A.).
B Lamp cable.
Cable H07 RN-F 18G 1,5 mm
with 16 x 16A M/F HARTING connectors.
C Electronique power supply.
D Analogue fader control (0/+10V).
+
1013
/
+
1013
M / BSM
B, BS, M & BSM
Section A - 9
C
Electronic
power supply unit.
2
length 3m fitted