5.1.4 LED source
• Do not touch the surface of the LED source (no contact with your hands or any tools).
• Do not put compressed air directly on the source.
• Contact a certified RJ distributor in case of residuals or other objects located on the
surface of the LED source.
5.1.5 Optics
The cleaning of optical parts (lenses) shall be carried out with solutions containing alcohol.
5.2
Analysis
If there is still a problem after the troubleshooting procedures (see section 6), contact
your local "RJ " distributor with the following information:
• Model, version and serial number of the product.
• Software version (available in menu 5/6 Fixture Info)
• Description of the problem.
5.3
LED reaction according to LED temperature
LED temperature
5°C → 60°C
60°C → 70°C
70°C → 90°C
5.4
Adjusting the maximum light output level
The maximum intensity level of the LED source can be adjusted in the 3/6 Fixture Param. →
Maximum setting menu in order to have a consistent fixture fleet. The dimming level is
then recalculated depending on the limitation.
5.5
Exploded view / Spare parts list
Available on
⇒
Or on request through our Service department
⇒
Lens tube access
Fan speed at minimum level
Fan speed increases progressively
Fan at maximum speed
LED intensity dims to zero output (overheating protection)
DMX and system LED feedback is red and temperature is available
in 4/6 Fixture Tools menu
www.robertjuliat.com
EN - 26 -
Fan
info@robertjuliat.fr