3.2.3 Data
Voltage
USITT DMX 512-A
PIN #
DMX
1
Shielding
2
DMX (-)
3
DMX (+)
4
Not used
5
Not used
Daisy chain:
Integrated terminal plug:
If no XLR connector is detected on DMX OUT connector, a 120Ω terminal plug is automatically activated.
Additional terminal plug on the last unit is not necessary.
DATA
Input connector
XLR 5-pin
DATA connectors
Description
Foil & Braided Shield
1
st
conductor of 1
st
twisted pair
2
nd
conductor of 1
st
twisted pair
1
st
conductor of 2
nd
twisted pair
2
nd
conductor of 2
nd
twisted pair
EN - 8 -
Output connector
XLR 5-pin
DMX OUT
DMX IN
Maximum:
32 units