Table 1 – General data
Note: Models with "A" as end letter = pressure kettle
Model
P70DG7
P8DG7
P70IG7
P8IG7
Table 2 – Sizes (see figure "Size of appliance and position of connections")
Specifications
Description
Unit of
measurement
Width (A)
Depth (B)
Height (C)
Vat diameter
Table 3 – General water data
Specifications
Description
Cold water connection
Hot water connection
Water pressure
Table 4 – Minimum output setting
G 20 – 20 mbar
G 30 – 28-30/37 mbar
Manuale d'istruzione per l'installazione, la manutenzione e l'uso
Pentole a gas P70.G7 / P8.G7
1.2. TECNICAL DATA
Type of
Vat usable
heating:
volume: I
Direct
50
Indirect
50
Models
P70.G7 / P8.G7
mm
mm
mm
mm
Unit of
measurement
mm
mm
kPa
P70.G7 / P8.G7
4,5 mbar
7 mbar
Pressure in the vat:
bar
--
--
700
700
900
400
Models
P70.G7 / P8.G7
10
10
50 – 300
05.11.01 - IT
Jacket pressure:
bar
--
0,5
pagina
31