2.5.2. REPLACEMENT OF INJECTORS FOR PILOT BURNER
–
The injector of the pilot burner can be reached by removing the lower front panel. Remove the side and
lower screws.
–
The pilot burner is in the front of the combustion chamber.
–
Unloose the screw and replace the injector with an appropriate one.
–
Once the appliance has been switched on, set the cock knob on the minimum position.
Remove the cock knob that will reveal a small hole on the panel of the appliance.
Turn the minimum adjustment screw on the cock with a screwdriver through the hole on the panel.
Warning!
Measure the minimum output pressure directly at the output pressure connection on
the injector tube (see figure "Measuring gas pressure")
Set the output pressure of the gas cock according to the figures stated in table 4 - Minimum output
setting).
After setting, seal the adjustment screw!
Warning!
After each conversion, it is necessary to check tightness and operation!
Warning! :
All maintenance operations shall only be performed by a technically qualified service
centre!
To ensure correct and safe operation, the appliance must be inspected and serviced at least once a year
only. Maintenance includes also to control the components and tear of pipes, feeding pipes etc..
-
It is advisable to replace worn components during maintenance operations to avoid the need for other
maintenance calls and unexpected failures.
It is also advisable to apply for a maintenance contract with the customer.
Manuale d'istruzione per l'installazione, la manutenzione e l'uso
Pentole a gas P70.G7 / P8.G7
2.5.3. MINIMUM OUTPUT ADJUSTMENT
2.6. MAINTENANCE OF THE APPLIANCE
05.11.01 - IT
pagina
37