Special Requirements For The Installation Site; Installation; Connection To Waterworks - Tecnoinox P70DG7 Instructions D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1.5. SPECIAL REQUIREMENTS FOR THE INSTALLATION SITE

The appliance belongs to the installation class A
system is required), so it is very important for the environment in which it is installed to be well-aired and
provided with all the safety openings prescribed for its power.
In addition, it is good policy to locate the appliance under an extractor hood so that cooking vapours can
be removed rapidly and continuously.
The gas supply system must be equipped with a rapid on off tap approved for the purpose.
This appliance requires two water connections: one for hot and one for cold water. Each line must be
fitted with an on-off valve.
Warning! :
The shutoff valves must both be located near to the appliance, within easy reach for
the user.
Remove all the packaging and check that the appliance is in perfect conditions. In case of visible
damage, do not connect the appliance and notify the sales point immediately.
Remove the PVC protection from the panels.
Dispose of packaging according to regulations. Generally material is divided according to composition
and should be delivered to the waste disposal service.
Maintain a distance of 5 cm between the back (chimney) of the appliance and the wall. There are no
particular prescriptions regarding side distances from other appliances or walls, however it is advisable to
leave enough space in case of maintenance and/or repairs. It is advisable to fit a suitable heat insulation
if the appliance is in direct contact with inflammable walls.
The appliance must stand level. Small differences in level can be eliminated by screwing or unscrewing
the adjustable feet: A significantly uneven or sloping stance can affect the operation of the appliance
adversely.
Warning! : Only qualified technicians must perform the installation, maintenance and test of the
appliance.
Warning! :
Before connecting any parts of the appliance to supplies, make sure that the latter is
equivalent the requirements stated in the technical data plate, if the appliance has
been designed for these supplies.
Water inlet pressure must be between 50 and 300 kPa, otherwise install a pressure regulator on the line
before the appliance.
Install a cut-off valve for each supply on the line before the appliance.
Water connections to 10 mm are fitted in the lower part on the left-hand side of the appliance.
Make connections according to regulations currently in force.
Manuale d'istruzione per l'installazione, la manutenzione e l'uso
Pentole a gas P70.G7 / P8.G7
(no direct connection of a chimney of flue exhaust
1
2.1. POSTIONING

2.2. INSTALLATION

2.2.1. CONNECTION TO WATERWORKS

05.11.01 - IT
pagina
34

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

P70ig7P8dg7P8ig7

Table des Matières