urmet domus BiBus II 1072 Manuel D'utilisation page 13

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Letter "O" identities the off-hook waiting time:
10s busy:
20s busy:
30s busy:
40s busy:
Door lock activation time
The relay controlling the door lock can be managed
in pulse mode (approximately 600 ms) or stabile
mode (from 1 to 30 s).
Letter "D" identities the lock activation time:
pulse:
door lock xy seconds:
Code button association
This is the step in which user codes to be
programmed are associated to each button
connected to the digitiser. The call code sequence
is: CxyzwPnm where xyzw is the user code and nm
is the calling station button number.
The user code xyzw can have the following values
• 0001-9999 for numeric code formats
• x000-x999 for alphabetic prefi x code formats (x
from A to J)
• 000x-999x for alphabetic suffi x code formats (x
from A to J)
• 0000
for direct calls to switchboard in day
mode.
• LLLL
for "staircase lights" function.
The button number nm depends on the position of
the terminal to which it is connected according to
the following table:
• 1÷18:
door unit with digitiser 1072/5
• 19÷34:
1st expansion module
• 35÷50:
2nd expansion module
• 51÷66:
3rd expansion module
• 67÷82:
4th expansion module
Once a code is programmed, press button ↵ to
automatically program call code xyzw+1 on button
nm+1. For example, the calling sequence C1000P01
↵↵↵ will program code 1000 on button 01, code
1002 button 02 and code 1002 on button 03.
1st edition system: this programming is not required.
Programming door phones in 2nd edition
systems using the programming adapter
The door phone programming sequence consists of
two steps:
A. Door phone booking (to be made on a calling
station).
B. Door phone programming (to be made in the
apartments).
DS1072-022A
O1
O2
O3
O4
D00↵
Dxy↵
A: Door phone booking
1. Insert adapter 1072/60 in the specifi c minidin
connector.
2. Press the user buttons to be associated with
the door phones once. The booking sequence
according to which the buttons are pressed must
be the same as the order in which the operator
will go to the apartments. DO NOT press the
switchboard call button or the "staircase lights"
function.
3. A beep will be heard after 30 seconds from last
pressing a user button (end of booking).
4. Leave the adapter 1072/60 in the digitiser and
go to the apartments to program the door
phones.
B: Door phone programming
1. Go to the fi rst booked user, hold the button
pressed and lift the door phone handset. Two
confi rmation beeps will be heard and the
LED will fl ash to indicate that it has been
programmed.
2. Go to the other booked users and repeat the
operations.
Refer to the attached sheet to remember the code/
button association sequence.
SEQUENZA DI ASSOCIAZIONE
ASSOCIATION SEQUENCE
N° DELLA POSTAZIONE (ID):
CALL MODULE NUMBER (ID):
SEQ.
NOMINATIVO
PULSANTE / CODICE
USER NAME
PUSHBUTTON / CODE
1
2
3
4
5
Associating 2/3 door phones in parallel in 2nd
edition systems using the programming adapter
To install two or three door phones in one apartment
and make them both ring when a call is received,
press the button related to the user twice or three
times with the door phones in parallel when booking
the door phones.
When you reach the apartment where the parallel
door phones are installed according to the
programming sequence, repeat the programming
sequence on both door phones.
Adding new users in 2nd edition systems using
the programming adapter
Insert the programming adapter in the digitiser
connector and program the user code of the button
which will call the unit. Press this button to book
programming and go to the user to program the
door phone.
PIANO
VARIE
FLOOR
VARIOUS
13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1072/19a

Table des Matières