Technical Data

Input
Nominal voltage U
N
BD 5980N.02:
BD 5980N.02/024:
Voltage range:
at 10 % residual ripple:
at 48 % residual ripple:
Nominal consumption:
Nominal frequency:
Delay time for simultaneity
demand:
Control contacts:
Current via control contacts: 35 mA at 24 V
Device fuse protection:
Output
Contacts
BD 5980N.02:
Operate / release time:
Contact type:
Nominal output voltage:
Thermal current I
:
th
Switching capacity
to AC 15:
to AC 15:
to DC 13:
to DC 13:
Electrical life
at AC 230 V, 6 A cos ϕ = 1:
Permissible operating
frequency:
Short circuit strength
max. fuse rating:
max.line circuit breaker:
Mechanical life:
General Data
Operating mode:
Temperatur range
Operation:
Storage:
Altitude:
Clearance and creepage
distances
rated impuls voltage /
pollution degree:
EMC:
Interference suppression:
Degree of protection:
Housing:
Terminal plate:
Housing:
Vibration resistance:
Climate resistance:
Terminal designation:
Wire fixing:
Mounting:
Weight:
Dimensions
Width x height x depth:
DC 24 V,
AC 24, 42, 48, 110, 115, 120, 230, 240 V
DC 24 V
+ AC 24 V
1)
2)
DC 24 V
1)
+ AC 42 V
2)
DC 24 V
1)
+ AC 110 V
2)
DC 24 V
1)
+ AC 127 V
2)
DC 24 V
1)
+ AC 230 V
2)
DC 24 V
1)
+ AC 240 V
2)
1)
DC 24 V at terminals A3-A4
2)
AC at terminals A1-A2
AC 0.8 ... 1.1 U
N
DC 0.9 ... 1.2 U
N
DC 0.8 ... 1.1 U
N
AC 24 V ... 230 V
4.0 VA
DC 24 V
2.5 W
50 / 60 Hz
0.5 s
2 x 1 NO contacts
The control lines must not exceed a
length of 30 m and must be routed
separately from line cables
internal with PTC
2 NO contacts
typ. 30 ms / typ. 30 ms
Relay, forcibly guided
AC 250 V
DC: see arc limit curve
see continuous current limit curve
3 A / AC 230V
IEC/EN 60 947-5-1
6 A / AC 230V at 0.25 Hz
2 A / DC 24 V
IEC/EN 60 947-5-1
6 A / DC 24 V at 0.1 Hz
> 5 x 10
switching cycles
5
max. 1200 switching cycles / h
6 A gG / gL
IEC/EN 60 947-5-1
C 10 A
10 x 10
switching cycles
6
Continuous operation
- 15 ... + 55 °C
- 25 ... + 85 °C
< 2.000 m
4 kV / 2
IEC 60 664-1
IEC/EN 62 061
Limit value class B
EN 55 011
IP 40
IEC/EN 60 529
IP 20
IEC/EN 60 529
Thermoplastic with V0 behaviour
according to UL subject 94
Amplitude 0,35 mm, IEC/EN 60 068-2-6
frequency10 ... 55 Hz
15 / 055 / 04 IEC/EN 60 068-1
EN 50 005
Plus-minus terminal screws M3.5,
box terminal with wire protection
DIN rail
IEC/EN 60 715
410 g
45 x 74 x 121 mm

Standard Type

BD 5980N.02 DC 24 V
Article number:
• Nominal voltage U
:
N
• Simultaneity:
• Output:
• Width:

Varianten

BD 5980N.02/61:
BD 5980N.02/024:
Ordering example for variants
BD 5980N .02 /024 DC 24 V + AC 230 V

Troubleshooting

Failure
Device cannot be activated

Maintenance and repairs

- The device contains no parts that require maintenance.
- In case of failure, do not open the device but send it to manufacturer
for repair.
14
0035300
DC 24 V
0,5 s
2 NO contacts
45 mm
with UL approval (Canada/USA)
dual voltage version
50/60 Hz
Nominal frequency
Nominal voltage
Variant
Contacts
Type
Potential cause
- Power supply not connected
- A safety relay is welded
(replace device)
- Feedback circuit Y1-Y2 not closed
- The 2-Hand-buttons have not been
operated simultaneously
within ≤ 0,5s