Characteristics
250
200
150
100
50
0
1
2
3
4
5
6
7
8
9
Switching current I [A]
M 6732
Arc limit curve with resistive load
Current via two contact rows
(same current for each contact row)
I (A)
Current via one contact row
7
6
5
4
3
2
1
-30 -20 -10
-0
10
20
Ambient temperature
Continuous current limit curve as a function of ambient temperature
10
°
T ( C)
30
40 50
60
M7241_a
Application Examples
L1
(+)
A1(+)
Y1
Y2
S13
BD5980N.02
A2(-)
S23
N
(-)
Two-hand control
Suited up to SIL1, Performance Level c, Cat. 1
L1
(+)
K1
K2
A1(+)
Y1
Y2
S13
BD5980N.02
A2(-)
S23
N
(-)
Two-hand control with contact reinforcement via external forcibly guided
contactors.
Suited up to SIL1, Performance Level c, Cat. 1
15
S1
S14
13
23
S24
14
24
S2
M6827_b
S1
S14
13
23
K1
K2
S24
14
24
S2
K1
K2
M6828_b
BD 5980N / 22.01.19 en / 114A