CHAFFOTEAUX ChaffoLINK 3318889 Notice Technique D'installation Et D'entretien page 59

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
4. Set the Clima Manager on Manual
5. Set the Summer/Winter/Off mode on
OFF
6. If there is an interface, the Clima
Manager must be removed to allow
the Gateway to be connected with
the boiler via the serial cable
Type 4
Activation of RD and RC on a system
with 2 or more plumbing zones
controlled by BUS devices.
System where there is an Chaff oteaux
multi-zone plumbing module to which
Bus zone management accessories
are connected such as an Chaff oteaux
Clima Manager and Room Sensors.
Actions required (Fig. 8):
- Remove the existing plumbing
module and replace it with a
plumbing module which has a
BridgeNet BUS Protocol
- Remove all temperature regulation
accessories in the system and
replace them with Chaff oteaux
Room Sensors, connecting them to
the new plumbing module via the
BridgeNet BUS connection.
- Install the Chaff olink Gateway and
connect it to the boiler through the
serial port and the TA input
- Connect the Chaff olink Gateway to
the new plumbing module via the
BridgeNet BUS connection.
(Fig. 7)
BUS
TA
SERIALE
BUS Bridgenet
Fig. 7
Clima Manager Room Sensor
BUS
PLUMBING
MODULE
Fig. 8
Room Sensor
BUS Bridgenet
PLUMBING
MODULE
59