Limited Warranty - dosatron D3 RE 3000 Manuel D'utilisation

Masquer les pouces Voir aussi pour D3 RE 3000:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
SYMPTOM
CAUSE
Injection
Under injection.
Suction of air.
Dirty or worn check
valve seal.
Maximum
flow exceeded
(cavitation).
Worn plunger seal.
Worn injection stem
Leaks
Leaks in the vicinity
Injector sleeve
of the fixing ring
seal is damaged or
under the body
positioned incorrectly.
housing.
Leaks between the
Injector stem seal
setting sleeve and
damaged, positioned
the blocking ring.
incorrectly or
missing.
Leaks between the
Screw-top seal is
body and screw-
damaged, positioned
top.
incorrectly or missing.
THE MANUFACTURER
DECLINES ALL RESPONSIBILITY IF THE DOSATRON
IS USED IN CONDITIONS THAT DO NOT CORRESPOND
TO THE OPERATING INSTRUCTIONS AS INDICATED
IN THIS MANUAL
©
DOSATRON INTERNATIONAL / 54
SOLUTION
1. Check the tightness
of the nuts in the
injection area.
2. Check suction tube.
Clean or replace it.
Reduce flow.
Replace it.
Replace it.
Replace it.
Replace it.
Unscrew the screw-top,
clean the seal seating,
replace or change the seal.
Position correctly the
screw-top.

Limited warranty

DOSATRON
INTERNATIONAL
S.A.S. will provide for replacement
of all parts shown to be defective
in material or workmanship during a
period of twelve months from the date
of purchase by the original purchaser.
To obtain warranty replacement of a
part, the DOSATRON must be returned
with original proof of purchase receipt
to the manufacturer or authorized
distributor and thereafter recognized
as defective after examination by the
technical services of the manufacturer
or distributor. The DOSATRON must
be flushed of any chemical and sent
to the manufacturer or distributor
prepaid, but will be returned free of
charge once repairs are made if found
to be covered by the warranty. Any
repairs made under warranty will not
extend the initial warranty period.
This
warranty
only
covers
circumstances where the part has
failed due to defects caused by the
manufacturing process. This warranty
is invalid if the defects are found
to be due to the product's misuse,
inappropriate use of tools, lack of
maintenance or defective installation
or
environmental
accidents
or
corrosion by foreign bodies and
liquids found within or in proximity to
the DOSATRON.
Before
using
any
aggressive
chemicals,
please
consult
your
distributor to confirm compatibility with
the dosing pump.
©
©
DOSATRON INTERNATIONAL / 55
DOSATRON INTERNATIONAL / 55
The seals and "o-rings" are not
covered under warranty, nor is
damage to the DOSATRON caused
by water impurities such as sand.
A filter (ex.: 300 mesh - 60 microns
depending on your water quality) must
be used in front of the DOSATRON for
the warranty to be valid.
DOSATRON
INTERNATIONAL
S.A.S. declines any responsibility
if the DOSATRON is not used in
compliance
with
the
operating
instructions
and
tolerances
as
indicated in this owner's manual.
This warranty gives you specific
legal rights and you may also have
other rights which vary from state
to state. But any implied warranty
or merchantability or fitness for a
particular purpose applicable to this
product is limited in duration to the
time period of this written warranty or
any implied warranty.
There is no warranty express or
implied relating in any way to products
used in conjunction with DOSATRON
INTERNATIONAL S.A.S. products.
The manufacturer or authorized
distributor shall not be liable for
incidental or consequential damage,
such as any economic loss, resulting
from breach of this written warranty or
any implied warranty.
There are no warranties, express or
implied, which extend beyond those
described above.

Publicité

Table des Matières
loading

Table des Matières