Dometic SINEPOWER DSP 1212C Instructions De Montage Et De Service page 33

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 67
SinePower
Overvoltage shutdown
Device
DSP1212C, DSP2012C
DSP1224C, DSP2024C
Undervoltage shutdown
Device
DSP1212C, DSP2012C
DSP1224C, DSP2024C
Temperature compensation with battery sensor
See fig. h
Input data for charging
Rated input voltage:
Input voltage range:
Input frequency:
Input frequency range
At 50 Hz:
At 60 Hz:
Rated current (at 230 V):
Efficiency:
Rated input current:
Maximum power correction
factor
EN
Overvoltage
warning
16 V
32 V
Undervoltage
warning
11 V
22 V
DSP1212C
DSP2012C
3.8 A
7.5 A
Overvoltage
Shutdown
16.5 V
33 V
Undervoltage
Shutdown
10.5 V
21 V
DSP1224C
230 Vw
180 – 264 Vw
50/60 Hz
47 – 53 Hz
57 – 63 Hz
3.8 A
>88 %
16 A
>0.95
Technical data
Restart
15.5 V
31 V
Restart
12.5 V
25 V
DSP2024C
7.5 A
31