Dometic SINEPOWER DSP 1212C Instructions De Montage Et De Service page 22

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 67
Before initial use
➤ Turn the selector button to set the floating voltage (12.8 V to 14.3 V in 0,1 V
steps).
➤ Press the selector button to save the selected value.
✓ The DSP-EM shuts off.
With connected battery sensor
➤ Turn the selector button until the number 9 is displayed.
➤ Press the selector button to save the value.
✓ The display shows the service code "S-12".
➤ Turn the selector button to set the battery type:
– 0: Lead acid
– 1: Gel
– 2: AGM
– 3: eStore
– 4: Customer
➤ Press the selector button to save the selected value.
✓ The display shows the service code "S-13".
➤ Turn the selector button to set the battery capacity (10 Ah to 249 Ah in 10 Ah
steps).
➤ Press the selector button to save the selected value.
✓ The display shows the service code "S-14".
➤ Turn the selector button to set the maximum charging current in percent (25 %,
50 %, 75 % or 100 % of the rated charging current).
➤ Press the selector button to save the selected value.
✓ The DSP-EM shuts off.
Reset the device to factory settings
➤ Switch on the system.
✓ The number "1" appears on the DSP-EM's display.
➤ Turn the selector button until the number 35 is displayed.
✓ The display shows the service code "S-35".
➤ Press the selector button to reset the device.
20
SinePower
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sinepower dsp 1224cSinepower dsp 2012cSinepower dsp 2024c

Table des Matières