Chauffe-eau d'intérieur sans réservoir à ventilation directe
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

RV53i
only
ANS Z21.10.3
CSA 4.3
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING
result causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Tankless Water Heater
Operation and Installation Manual
RV53i .................. REU-VB2020FFU-US
RV53e ................. REU-VAM1620W-US
Certified for installation in manufactured (mobile) homes.
Table of Contents .............................................. 2
Consumer Safety Information ........................... 4
Operating Instructions ....................................... 5
Maintenance ..................................................... 9
Error Codes ..................................................... 10
Installation Instructions ................................... 14
Consumer Support .......................................... 39
French Version ................................................ 42
Register your product at www.rinnairegistration.com or call
1-866-RINNAI1 (746-6241)
If the information in these instructions is not
followed exactly, a fire or explosion may

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Rinnai RV53i

  • Page 1: Table Des Matières

    Tankless Water Heater Operation and Installation Manual RV53i ....REU-VB2020FFU-US RV53e ....REU-VAM1620W-US Certified for installation in manufactured (mobile) homes. Table of Contents ..........2 Consumer Safety Information ......4 Operating Instructions ........5 Maintenance ............. 9 Error Codes ............. 10...
  • Page 2 French Version ..........42-59 Pipe Sizing Procedure - Example .... 17 Water Piping Isolation Valves and Pressure Relief Valves ......18 General Instructions ........ 19 Pressure Relief Valve ......19 Freeze Protection ........19 RV53i & RV53e Operation and Installation Manual...
  • Page 3: Rv53I

    (mobile) homes * Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice. The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the purpose of input adjustment.
  • Page 4: Consumer Safety Information

    • Power Failure: The appliance will cut off the gas if it loses electrical power. Description of Operation The Rinnai water heater is one of the most advanced Installation of the temperature controller is highly water heaters available. It provides a continuous recommended.
  • Page 5: Operating Instructions

    Operating Instructions The RV53i and RV53e models do not come with a temperature controller. There are several models of temperature controllers that can be purchased separately. A maintenance display or status monitor is provided in the front panel to indicate operating status and error codes.
  • Page 6: Temperature Controller Settings

    Water temperatures over 125º F (52º C) can cause severe burns or scalding. Refer to the Danger Alert on water temperatures. Rinnai shall not, in any event, be liable for damages resulting from such misuse or misapplication.
  • Page 7: Using The Water Smart / Bath Fill Function

    3. Press the “Temp” ▲ or ▼ buttons • Monitor and remain by the bath to obtain the desired temperature Over Filling while the water is running. setting. • Use a low bath fill volume less than 25 gallons. RV53i & RV53e Operation and Installation Manual...
  • Page 8: Filling The Tub

    Press the “Function” button twice within 10 seconds to set the clock. Press the ▲ or ▼ button to reach the desired time. The clock on the BC-100V automatically shows the time which has been set on the MC-100V. RV53i & RV53e Operation and Installation Manual...
  • Page 9: Maintenance

    If you receive Error Code “LC”, refer to the procedure, Flushing the Heat Exchanger. Refer to the section on Water Quality to see if your water needs to be treated or conditioned. (When checking maintenance code history, “00” is substituted for “LC”.) RV53i & RV53e Operation and Installation Manual...
  • Page 10: Error Codes

    Error Codes The Rinnai water heater has the ability to check its own operation continuously. If a fault occurs, an error code will flash on the display in the front panel and on the temperature controller if installed. This assists with diagnosing the fault and may enable you to overcome a problem without a service call.
  • Page 11 Ensure you have at least the minimum flow rate required to fire unit. Ensure turbine spins freely. Measure the resistance of the water flow control sensor. Check for DC shorts at components. RV53i & RV53e Operation and Installation Manual...
  • Page 12: Trouble Shooting For Common Issues

    Make sure there is gas, water, and electricity to the During colder weather when the exhaust temperature Rinnai water heater (power is turned on and the gas is is much hotter than the outside air, the exhaust fumes turned on).
  • Page 13: Flushing The Heat Exchanger (Error Code: Lc Or 00)

    13. Restore electrical power to the water heater. CLEAN THERMISTORS Remove and clean thermistors with a soft cloth or sponge after removing O-rings. Cleaning solution is 4 gallons of undiluted virgin, food grade, Circulating Pump white vinegar. RV53i & RV53e Operation and Installation Manual...
  • Page 14: Rv53E

    Rinnai highly recommends all installers attend a product knowledge class. The RV53i and RV53e are certified for installation in manufactured (mobile) homes. For information on a Rinnai Training Course or for questions on installation call 1-800-621-9419.
  • Page 15: Clearances From Appliance

    Refer to the brackets weight of the water heater in the Specifications section. NOTE: Rinnai water heaters should be installed in an upright position. Do not install upside down or on it side. RV53i & RV53e Operation and Installation Manual...
  • Page 16: Electrical Connection

    Rinnai water heater. If the Rinnai water heater is not of the gas type that the • The gas supply line shall be gas tight, sized, and so building is supplied with, DO NOT connect the water installed as to provide a supply of gas sufficient to heater.
  • Page 17: Pipe Sizing Procedure - Example

    BTU/hour. Example: The heating value of natural gas for your location is 1000 BTU/FT . The gas input of the RV53i is 150,000 BTU/HR. Additional appliances at the location require 114,000 BTU/hr. Therefore the cubic feet per hour = (150,000 + 114,000) / 1000 = 264 FT /HR.
  • Page 18: Water Piping

    (perpendicular to the drain Please note that only the PRV in this package is portion of the body). certified by CSA International as an approved item. RV53i & RV53e Operation and Installation Manual...
  • Page 19: General Instructions

    • Ensure that the water filter on the Rinnai water • Purge the water line to remove all debris and air. heater is clean and installed.
  • Page 20: Freeze Protection Methods

    2. Close the gas and water valves and turn off the power. 3. Wait until the water thaws. Check by opening the water supply valve. 4. Check the water heater and the piping for leaks. RV53i & RV53e Operation and Installation Manual...
  • Page 21: Freeze Protection Piping

    Rinnai water to prevent freezing damage. Water Heater The unit may be drained manually. However, Rinnai highly recommends that drain down solenoid valves be installed that will automatically drain the unit if power is lost. Rinnai also recommends the installation...
  • Page 22: Error Indication Or Air Handler Control Switch (Rv53I)

    Error Indication or Air Handler Control Switch (RV53i) When using the Rinnai water heater with an Error Indication Switch, switch No. 4 in the bank of 8 switches should be in the off position. This is the default position. To connect the water heater to the Rinnai Air Handler, the Control Switch is necessary to function as the electrical connection.
  • Page 23: Recommended Piping For Circulation Systems

    IMPORTANT: Connect the building Electric Water return line to the hot water supply line Heater as close as possible to the Rinnai Water Building Heater. Fixtures This is not an engineered drawing. It is intended only as a guide and not as a replacement for professionally engineered project drawings.
  • Page 24: Venting Instructions (Rv53I) Intake / Exhaust Guidelines

    • Vent diameter must not be reduced. If it becomes necessary to access an enclosed vent system for service or repairs, Rinnai is not responsible • Do not connect the venting system with an existing for any costs or difficulties in accessing the vent vent or chimney.
  • Page 25: Maximum Vent Length

    If you have a longer vent length, switch no. 1 is required to be in the OFF position. This ensures the water heater will run properly. Blocked flue error codes and shutdowns may result if switch no. 1 is not in the correct position. Vent Products Listed and Tested Vent Products for RV53i ....... REU-VB2020FFU-US Manufacturer Product Parts...
  • Page 26: Flue Installation - Concentric Venting (Rv53I)

    5. Install the 4 screws at the vent top and tighten the 4 screws at the bracket. Secure the first vent component to the water heater Securing Screw with one self-tapping screw at the hole located above the condensate collector. RV53i & RV53e Operation and Installation Manual...
  • Page 27: Flue Terminal Clearances

    For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local installation codes and the requirements of the gas supplier. Clearance to opposite wall is 24 inches (60 cm) for Canada and US. RV53i & RV53e Operation and Installation Manual...
  • Page 28: Additional Clearances

    C O R N E R (1.52 m) vertically 60" between Rinnai terminals (0.61 m) to wall or parapet 24" (1.52 m) between (0.30 m) between 60" Rinnai terminals Rinnai terminals at at different levels same level 12" RV53i & RV53e Operation and Installation Manual...
  • Page 29: Connecting Multiple Water Heaters

    MSA-2S. The RV53e can use Rinnai pressure activation valves (PVA’s) can be used to manifold 2 to 5 Rinnai water heaters in order to produce a stable water temperature and allow the water heaters to run efficiently. Water heaters will turn on as necessary to meet the demand for hot water.
  • Page 30 CAN/CGA-B149.1 ou CAN/CGA-B149.2 Codes d'Installa- tion. RV53i & RV53e Operation and Installation Manual...
  • Page 31: Temperature Controller Installation Location

    328 ft (100 m) controller to the water heater depends on the total number of wired controllers connected to the water 164 ft (50 m) heater. 3 or 4 65 ft (20 m) RV53i & RV53e Operation and Installation Manual...
  • Page 32: Mounting The Controller (Rv53I)

    Do not connect the temperature controller to the 3. Run the cable between the controller and the 120VAC terminals provided for the optional Rinnai water heater or the controller and the solenoid drain valves. other controller. All service and wiring should be performed by a 4.
  • Page 33: Mounting The Controller (Rv53E)

    1. Determine a suitable location for the controller. 2. Make three holes in the wall as shown. 3. Run the cable between the controller and the Rinnai water heater or the controller and another controller. 4. Remove the face plate from the temperature controller using a screwdriver.
  • Page 34: Operating Instructions

    1. Turn off all electric power to the appliance using 3. Locate the manual gas valve on the side of the the ON/OFF button. heater. Turn the manual valve clockwise to the full OFF position. 2. Set the thermostat to lowest setting. RV53i & RV53e Operation and Installation Manual...
  • Page 35: Technical Data

    Technical Data Pressure Drop Curve RV53e RV53i Water Flow (gpm) Outlet Flow Data RV53i RV53e delta T - Temperature Rise (ºF) RV53i & RV53e Operation and Installation Manual...
  • Page 36: Space Heating

    Iron Components Do not use Rinnai water heaters directly for space heating applications involving iron radiators or applications with any iron components. Iron components may oxidize creating rust that will clog the inlet filter of the Rinnai water heater. RV53i & RV53e Operation and Installation Manual...
  • Page 37: Dimensions

    2.0 (50) From base to hot connection 1.7 (42) 1.6 (42) * This is the minimum dimension from the wall. The wall bracket is adjustable to allow an additional 1.57 inches (40 mm). RV53i & RV53e Operation and Installation Manual...
  • Page 38: Ladder Diagrams

    Ladder Diagrams RV53i RV53e RV53i & RV53e Operation and Installation Manual...
  • Page 39: Consumer Support

    Limited Warranty What is covered? This Warranty covers any defects in materials or workmanship when the product is installed and operated according to Rinnai written installation instructions, subject to the terms within this Limited Warranty document. This Warranty applies only to products that are installed correctly.
  • Page 40 Replacement of the product may be authorized by Rinnai only. Rinnai does not authorize any person or company to assume for it any obligation or liability in connection with the replacement of the product. If Rinnai determines that repair of a product is not possible, Rinnai will replace the product with a comparable product at Rinnai’s discretion.
  • Page 41: State Regulations

    State Regulations NOTICE BEFORE INSTALLATION Rinnai direct-vent appliance must be installed by a state qualified or licensed contractor and a properly trained Rinnai Installer. If you are not properly trained, you must not install this unit. IMPORTANT: In the State of Massachusetts (248 CMR 4.00 & 5.00)
  • Page 42: Que Faire Si Vous Sentez Une Odeur De Gaz

    Espacements pour terminaison de cheminée l'appareil installé. (ANSI Z21.10.3, CSA 4.3) ......... 54 CONSOMMATEUR : Conservez ce manuel Installation de conduit de cheminée (RV53i) ..55 comme référence ultérieure. Instructions d'utilisation ........56 Diagramme en escalier ........57 Support à la clientele / Pour une traduction complète du manuel en français,...
  • Page 43: Instructions D'utilisation

    à distance et la température réelle au robinet, du fait des conditions d'environnement, ou de la longueur de tuyauterie depuis le chauffe-eau. Manuel d'installation et d’utilisation – RV53i & RV53e...
  • Page 44: Plages De Température Avec Un Contrôleur De Température

    à une température sûre. Arroser des températures plus de 125º F (52º C) peut causer des brûlures ou scalding sévère. Se référer à l'Alerte de Danger sur les températures d'eau. Rinnai ne fait pas, en tout cas, être responsable des dommages qui résultent de tel usage impropre ou tel mauvais usage.
  • Page 45: Entretien

    (Lors de la vérification de l'historique des anomalies pour l'entretien, le code « 00 » aura remplacé « LC ».) Manuel d'installation et d’utilisation – RV53i & RV53e...
  • Page 46: Instructions D'installation

    être obstrué. • • La RV53i ne doit pas être installé à l'extérieur. Cet appareil ne convient pas pour une utilisation dans une application comme le chauffage d'eau de piscine ou de •...
  • Page 47: Écartements Par Rapport À L'appareil

    Remarque : Les chauffe-eau de Rinnai doit être installé dans une position verticale. N'installez pas à l'envers ou sur ce côté. Manuel d'installation et d’utilisation – RV53i & RV53e...
  • Page 48: Installation À Altitude Élevée

    être rincée avec de l'eau -eau Rinnai. Un raccord union peut être utilisé sur la après le test, sauf si vous avez pu déterminer que la connexion au-dessus de la vanne de coupure pour solution de détection utilisée n'était pas corrosive).
  • Page 49: Tuyauterie D'eau

    (perpendiculaires à la portion peut causer des dommages ou des blessures. drainage du corps). Prière de noter que le VDP inclus dans cet emballage est certifié par CSA International en tant qu’item approuvé. Manuel d'installation et d’utilisation – RV53i & RV53e...
  • Page 50: Soupape De Sûreté

    à eau potable. potable. • • Purgez la conduite d'eau pour en éliminer les débris et Le filtre d’eau du chauffage Rinnai dout être propre et l'air. Des débris entrant dans le chauffe-eau Rinnai installé. pourraient l'endommager. Soupape de sûreté...
  • Page 51: Tuyauterie Recommandée Pour Installation De Base

    Confer Soupape de décharge Pressure Relief Valve Solenoid Valve Électrovanne with local building officials before installation. Manuel d'installation et d’utilisation – RV53i & RV53e...
  • Page 52: Instructions De Ventilation (Rv53I) Consignes Pour Aspiration/Évacuation

    AVIS l'appareil. Des dispositions doivent être prises pour éviter que du • Le chauffage de l'eau RV53i a un collecteur de condensat condensat n'entre dans le chauffe-eau. Sans un drainage intégré. adéquat et un rejet, le condensat peut endommager •...
  • Page 53: Longueur Maximum De Ventilation

    Téléphone : 800-772-0739 Téléphone : 800-835-2830 Fax : 678-829-1666 Fax : 413-863-4803 316-943-2351 Site Web : www.rinnai.us Courriel : custsvc@heat-fab.com Fax : 316-943-2717 Site Web : www.heatfab.com Courriel : info@mtlfab.com Site Web : www.metal-fabinc.com Manuel d'installation et d’utilisation – RV53i & RV53e...
  • Page 54: Espacements Pour Terminaison De Cheminée

    Pour les espacements non spécifiés dans ANSI Z223.1/NFPA 54 ou CSA B149.1, il faut appliquer les valeurs conformes aux normes locales d'installation et aux exigences du fournisseur de gaz.. L'espacement par rapport au mur opposé est de 24" (60 cm) pour Canada et USA. Manuel d'installation et d’utilisation – RV53i & RV53e...
  • Page 55: Installation De Conduit De Cheminée (Rv53I)

    5. Remettez les 4 vis du haut de ventilation et resserrez les 4 vis du support. Fixez la pièce de ventilation connectée sur le chauffe-eau Vis de fixation avec une vis autotaraudeuse dans le trou situé au dessus du collecteur de condensat. Manuel d'installation et d’utilisation – RV53i & RV53e...
  • Page 56: Instructions D'utilisation

    Repérez la vanne de gaz manuelle sur le côté du son bouton M/A. chauffe-eau. Fermez-la en la tournant à fond dans le sens horaire (position OFF). Réglez le thermostat sur la consigne la plus basse. Manuel d'installation et d’utilisation – RV53i & RV53e...
  • Page 57: Diagramme En Escalier

    THERMISTANCE DE SORTIE D'EAU THERMISTANCE DE SORTIE D'EAU 2 THERMISTANCE D'ÉCHA- CIRCUIT DE CIRCUIT DE GEUR THERMIQUE THERMIS- THERMIS- TANCE TANCE THERMISTANCE D'ÉCHA- THERMISTANCE DE GEUR THERMIQUE BRÛLEUR THERMISTANCE DE TEMPÉRATURE D'AIR Manuel d'installation et d’utilisation – RV53i & RV53e...
  • Page 58: Support À La Clientele

    Cette garantie couvre tous défauts dus aux matériaux et à la main d'œuvre quand le produit a été installé et utilisé en suivant les instructions écrites d'installation de Rinnai, dans les termes décrits dans ce document de garantie limitée. Cette garantie s'applique seulement aux produits qui sont installés correctement.
  • Page 59 Rinnai le remplacera par un produit comparable, à sa discrétion. Si un composant ou un produit retourné à Rinnai est trouvé sans défaut du aux matériaux ou à la main d'œuvre, ou qu'il est déterminé qu'il a été...
  • Page 60 060 00012 31348 2 (VAM1620W, VB2020FFU) U287-1821X01(00) © 2010 Rinnai America Corporation Printed in Japan...

Ce manuel est également adapté pour:

Rv53eReu-vb2020ffu-usReu-vam1620w-us

Table des Matières