Freeze Protection Methods; Manual Draining Of The Water Heater; Running A Low Volume Of Water Through The Water Heater To Prevent Freezing; When The Water Heater Or External Piping Has Frozen - Rinnai RV53i Manuel D'installation Et D'utilisation

Chauffe-eau d'intérieur sans réservoir à ventilation directe
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Freeze Protection Methods

Manual draining of the water heater

WARNING
If the water heater is not going to be used during a period of possible freezing weather, it is recommended that the
water inside the water heater be drained.
To manually drain the water:
1. Shut off cold water supply and gas supply.
2. Turn off the temperature controller.
3. Disconnect the power to the water heater.
4. Open hot water drain plug at the hot water outlet.
5. Remove water filter to drain the cold water.
If an isolation kit is installed, remove the drain caps on
both isolation valves and open both valves above the
caps (blue and red valve handles).
To resume normal operation:
1. Confirm that all water drain plugs are removed, that
the gas supply is turned off, and that all taps are
closed.
2. Screw in the hot water drain plug.
3. Screw in the water filter in the cold water inlet.
If the isolation kit was used to drain the unit, replace the drain caps
and close both isolation valves (blue and red valve handles).
4. Open the cold water supply.
5. Open a tap and confirm that water flows, and then close.
6. Turn on the power.
7. After confirming that the temperature controller is off, turn on
the gas supply.
8. Turn on the temperature controller.

Running a low volume of water through the water heater to prevent freezing

If the temperature exceeds the ability of the water heater to freeze
protect itself, or if power is lost, the following steps may prevent the
water heater and external piping from freezing. (Units connected with
MSA or EZConnect should be drained to prevent freezing if not in use.)
1. Turn the water heater off.
2. Close the gas supply valve.
3. Reduce the flow to about 0.1 gal/min or to where the stream is about
0.2 inches thick.

When the water heater or external piping has frozen

1. Do not operate the water heater if it or the external piping is frozen.
2. Close the gas and water valves and turn off the power.
3. Wait until the water thaws. Check by opening the water supply valve.
4. Check the water heater and the piping for leaks.
20
To avoid burns, wait until the equipment cools down before draining the water. The
water in the appliance will remain hot after it is turned off.
RV53i & RV53e Operation and Installation Manual
Hot water
Hot water
outlet
drain plug *
ON!
COLD
HOT
Water
filter
Cold water
inlet
* Use a wrench or other
tool to unscrew the hot
water drain plug.
0.1 gal/min or
about 0.2 inch
thick

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Rv53eReu-vb2020ffu-usReu-vam1620w-us

Table des Matières