23. 7 Inspect the parts
Once the saniti sing, rinsing and drying operati ons are complete, proceed as follows:
Step
1
check that all parts are perfectly clean and dry
2
check that they are not damaged or too worn
3
replace worn parts with new identi cal parts supplied only by the manufacturer
4
install the parts perfectly dry
5
restore electrical power supply
Once the internal operati ng temperature has been reached, it is possible to load the products.
24. Load the refrigerant
DANGER! Coolant gas. Explosion. Asphyxia, alterati on of cardiac pace, frostbite, anaes-
theti c eff ects.
BEFORE ANY OPERATION EMPTY THE ENTIRE SYSTEM!
WARNING! FIRE. Burns. Asphyxia
NEVER use naked fl ames and electrical tools next to gas
Only specialist technicians may recharge the refrigerant or work on the gas circuit according
to the European Regulati on 517/2014
Check that refrigerant circuit is perfectly sealed
Only use original approved spare parts
MINI ASTANA LX with built-in condensing unit:
The refrigerant charge for Mini Astana LX cabinets with built-in condensing unit is less
than 5 tonnes of CO
517/2014, it is not mandatory to check for leaks or to adjust it.
25. Dismantle the cabinet
All operati ons such as the transportati on and processing of waste must be carried out only
by specialist and authorised technicians according to the regulati ons in force in the country
of disposal.
i
This product is made up by 75% of recyclable materials
Preparati on
• recover the refrigerant.
• remove the lubricati ng oil.
Obligati ons
• dismantle the cabinet in accordance with the local laws on waste disposal and
• according to the legislati on in force, the counter is considered as dangerous
• take the intact parts of the refrigerati on circuit to specialised refrigerant recy-
60
, therefore according to Arti cle 4 paragraph 1 of the EU Regulati on
2
with respect for the environment in which we live.
waste and falls under the category of separate collecti on and cannot be treat-
ed as domesti c waste or be sent to landfi ll.
cling centres.
Acti on
05060194 01 05-2022