TESTING
NOTE: When the pump is installed in a basin with a sealed cover, you cannot observe the operation of
the float switch. The cover usually will have a spare hole that is blocked with a rubber plug. Remove
this plug to observe the switch operation during testing.
1.
Check the pump label for proper voltage required.
WARNING! Do not connect to a voltage other than that shown.
2.
Plug the power cord directly into a GFCI equipped electrical outlet.
3.
Run water into the basin until the pump starts.
4.
Be sure the check valve in the discharge line is open.
5.
Allow the pump to operate through several on / off cycles.
MAINTENANCE
1.
Cycle the pump at least once every month to be sure that the system is working properly.
2.
Before removing the pump from the basin for service, always disconnect the electrical power
source to the pump and the control switch. Do not lift the pump by the power cord.
WARNING! Sudden starts. If the power is on to the pump when the thermal overload resets, the
pump may start without warning. If you are working on the pump, you may get an electrical shock
or the impeller may catch fingers or tools.
WARNING! Disconnect the pump from the power source before servicing.
NOTE: This pump has no serviceable parts. The motor housing of the pump is completely sealed and
requires no service. Disassembly of the motor housing or alteration of the power cord will void all
warranties. The power cord on this pump cannot be replaced. If it becomes damaged, the entire pump
must be replaced.
DISINFECT THE PUMP
Place the pump in an area where it can be cleaned thoroughly. Remove all scale and deposits on
the pump.
NOTE: Wear rubber or plastic gloves when handling the pump for service. Completely submerge the
pump in a disinfectant solution (Clorox or chlorine bleach) for at least one hour before disassembling
the pump.

LUBRICATION

The pump is permanently lubricated. No oiling or greasing is required in normal operation.