10. Before installing this product, have the electrical circuit checked by an electrician to ensure
proper grounding.
11. Do not lift the pump by the power cord.
12. Be certain the pump power source is disconnected before installing or servicing the pump.
13. Check the voltage on the motor nameplate and make sure that the line voltage of the
electrical current supply is the same.
14. Do not expose the pump to freezing temperatures. Freezing could cause severe damage and
will void the warranty.
15. Do not insert fingers or any object into the pump or motor openings.
16. Do not run the pump dry. Dry running can overheat the pump, (causing burns to anyone
handling it) and will void the warranty.
17. The pump normally runs hot. To avoid burns when servicing the pump, allow it to cool for
twenty minutes after shutdown before handling it.

ELECTRICAL SAFETY

WARNING! Hazardous voltage can shock, burn or kill. When installing, operating or servicing this
pump, follow the safety instructions listed below.
1.
Do not splice the electrical power cord.
2.
Do not allow the plug on the end of the electrical cord to be submerged.
3.
Do not use extension cords. They are a fire hazard and can reduce the voltage sufficiently to
prevent pumping and / or damage the motor.
4.
Do not handle or service the pump while it is connected to the power supply.
5.
Do not remove the grounding prong from the plug or modify the plug. To protect against
electrical shock, the power cord is a three-wire conductor and includes a three-prong
grounded plug. Plug the pump into a three-wire, grounded, grounding-type receptacle.
Connect the pump according to the NEC or CEC and local codes.
6.
Ground the motor before connecting to an electrical supply.
7.
Failure to ground the motor can cause severe or fatal electrical shock.
8.
Do not ground to a gas supply line.
9.
To avoid dangerous or fatal electrical shock, turn off the power to the motor before working
on electrical connections.
10. The supply voltage must be within 10% of the nameplate voltage. Incorrect voltage can
cause fire or seriously damage the motor and voids the warranty. If in doubt, contact a
licensed electrician.
11. Use the specified wire size.
12. Meet all national electrical code and local codes for all wiring.
13. Do not handle a pump or pump motor with wet hands, or when standing on a wet or damp
surface or in water.
14. Always disconnect the power source before performing any work on or near the motor or its
connected load.
15. Protect yourself against electric shocks when working on electrical equipment. Avoid body
contact with grounded surfaces. There is an increased chance of electrical shock if your body
is grounded.
WARNING! A qualified electrician should perform all wiring.