Mounting the hood body
• Remove the metal grease filters by turning the handles
provided.
• Adjust the two screws Vr, on brackets 11a, to a mini-
mum.
• Hook the hood canopy onto the two brackets 11a.
• From inside the hood canopy, adjust the screws Vr to
set the Hood Canopy level.
• Tighten the safety screws 12a.
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ø 150 or
120 mm, the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Remove possible charcoal filters.
RECIRCULATION VERSION AIR OUTLET
• Insert the connection extension pieces laterally 14.1 in
connection 15.
• Insert the Connector 15 into the Support bracket 7.3
and fix it with a screw.
• Make sure that the outlet of the extension pieces 14.1
is horizontally and vertically aligned with the chimney
outlets.
• Connect the air outlet connection 15 to the hood body
outlet using either a flexible or rigid pipe ø 150 mm,
the choice of which is left to the installer.
• Ensure that the activated charcoal filters have been
inserted.